Pm90 powermeter

2.Advanced setting

3.Check the data

5.Battery replacement

6.Safe use

7.Specs and maintanence

8.Toubleshootings

1)

 

set system time

2) connect to appliance
3) check the power data
4) Manually turn on/off switch

1)

 

Turn on/off the back light

2) Currency select
3) 
4) 

Set local power tarrif
Set GHG(Green House Gas) coefficient

5) Countdown setting
6) Overload setting

1)

 

Value button

2) Display button

4.History data

1) Check data from graphic
2) Read accurate data

Summary of Contents for PM90

Page 1: ...gs 1 set system time 2 connect to appliance 3 check the power data 4 Manually turn on off switch 1 Turn on off the back light 2 Currency select 3 4 Set local power tarrif Set GHG Green House Gas coefficient 5 Countdown setting 6 Overload setting 1 Value button 2 Display button 4 History data 1 Check data from graphic 2 Read accurate data ...

Page 2: ...Y SET OK HISTORY RESET VALUE DISPLAY SET OK HISTORY RESET Press OK to NEXT menu Press button to set hour VALUE DISPLAY SET OK HISTORY RESET VALUE DISPLAY SET OK HISTORY RESET Press HISTORY to cycle choose Hour Minute Seconds Press button to set minute and seconds VALUE DISPLAY SET OK HISTORY RESET VALUE DISPLAY SET OK HISTORY RESET Press OK to NEXT menu Press OK 10 times to quite setting mode Fini...

Page 3: ... 3 Check the on going data on PM90 connect appliance to Pm90 Briefly press VALUE button to cycle switch the data displayed Votage Current Wattage Max Current Max Wattage Frequency Cos phi 4 Switch on off the output VALUE DISPLAY SET OK HISTORY RESET Press and hold VALUE button for 3 seconds to turn ON OFF the switch Hold 1 ...

Page 4: ...f the back light will expand battery life sharply VALUE DISPLAY SET OK HISTORY RESET VALUE DISPLAY SET OK HISTORY RESET Press OK to NEXT menu Press and hold the set button enter setting mode TIME SETTING refer to Quick set 2 1 VALUE DISPLAY SET OK HISTORY RESET VALUE DISPLAY SET OK HISTORY RESET Press button to switch the BL backlight on off status it s highly recommended not to turn on the back l...

Page 5: ...f 1 time setting Set RATE 1 value Press HISTORY button to switch between the 4 digits 2 VALUE DISPLAY SET OK HISTORY RESET Press buttons to change the value from 0 9 after correctly enter your tariff press OK to advance Tariff 1 Day 8 00 18 00 0 177 ponds kwh Tariff 2 Night 18 00 8 00 0 127 ponds kwh 2 Currency select Pm90 provide you different currency unit for power cost calculation VALUE DISPLA...

Page 6: ...iff 2 time Press HISTORY button to switch between the 4 digits VALUE DISPLAY SET OK HISTORY RESET Press buttons to change the value from 0 9 after correctly enter tariff time press OK to advance to next menu VALUE DISPLAY SET OK HISTORY RESET Press OK enter next menu VALUE DISPLAY SET OK HISTORY RESET Set tariff 1 time Press HISTORY button to switch between the 4 digits VALUE DISPLAY SET OK HISTOR...

Page 7: ...e carbon emission factor vary in different area typically value 0 883 kgco Kwh VALUE DISPLAY SET OK HISTORY RESET VALUE DISPLAY SET OK HISTORY RESET Press OK advance to next menu Press HISTORY button to switch between the 4 digits 2 VALUE DISPLAY SET OK HISTORY RESET Press buttons to change the value from 0 9 Congrats you finished the power tariff setting the appliance power spend will precisely c...

Page 8: ...f the appliance Power consumption count down set a target power consumption to switch off the appliance Spend count down set a target spend to switch off the appliance Press buttons to change the value from 0 9 after correctly enter press OK to advance VALUE DISPLAY SET OK HISTORY RESET Power count down VALUE DISPLAY SET OK HISTORY RESET VALUE DISPLAY SET OK HISTORY RESET Spend count down do the s...

Page 9: ... OK HISTORY RESET NOTE 1 once the overload is triggered the beeper inside will beep for alarm and switch will be turned off 2 the adjusting range for Pm90 on Ampere is 0 16A if you the value to be 0 means no overload alarm and switch protection process 3 you can set both current and wattage overload alarm the alarm and switch will trigger the first arrived overload VALUE DISPLAY SET OK HISTORY RES...

Page 10: ...e Frequency Cos phi On going volt current power Peak current Peak power AC frequency Power factor On going On going 2 Display button VALUE DISPLAY SET OK HISTORY RESET Briefly press DISPLAY button to check the system data on middle area System time VALUE DISPLAY SET OK HISTORY RESET Total power consumption Tariff rate running Display VALUE DISPLAY SET OK HISTORY RESET Total working time ...

Page 11: ... RESET Time countdown VALUE DISPLAY SET OK HISTORY RESET VALUE DISPLAY SET OK HISTORY RESET Power countdown VALUE DISPLAY SET OK HISTORY RESET VALUE DISPLAY SET OK HISTORY RESET Spend countdown back to first screen Congrats Now you know how to check out all data collected by PM90 ...

Page 12: ...ue e g 2 bars 2 watts The value of the bar can be different depend on what unit value it shows up on right corner it could be any combinations please notice that when you read the data VALUE DISPLAY SET OK HISTORY RESET 2 Check accurate power data of each day month Hold Press and hold HISTORY button to enter accurate data reading mode you will read the exact power data of each day week VALUE DISPL...

Page 13: ...History data 4 VALUE DISPLAY SET OK HISTORY RESET Press OK to to quit the history data mode and return to main menu ...

Page 14: ...zed please replace batteries with this notice 2 Batteries are designed to maintain the system time of this device if the battery is used to support back light of device they will run out very easy we strongly recommand you to turn off the back light during battery power supply and please be advised turning off the back light in BL menu will only turn off the back light during battery power supply ...

Page 15: ...to check the outlet overload power before plug the appliance on through Pm90 2 Make an overload setting once you choose the plug for example your target outlet is 10A overload current Plug the Pm90 to the outlet and Do the overload setting on Pm90 please refer to overload setting Please be aware that this device place a role as a bridge between household outlet and appliance so the appliance is co...

Page 16: ...V 270V Current range 0 16A Current accuracy 0 1A Power display range 0 3680 Watts Power accuracy 0 1Watts Standby current draw 50uA GHG range 0 999 999 kg History data latest 7 days Month Working Temperature 10 50 Maintenance Don t leave the batteries out of power in the device Frequently check them and replace in time ...

Page 17: ...turned off Why the beep is on If you set either 3 of the count down functions the beeper will be on for a while once program finish You appliance load trigger the target How long the battery last 1 If Pm90 is plugged on socket there s 0 current draw from battery 2 If Pm90 off the outlet and back light is config to be off will last 120 days with no operation on buttons Battery life is based on how ...

Page 18: ...ul interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the r...