background image

XP-Series

   

10

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION !!

CAUTION :

  REPLACE WITH SAME           TYPE FUSE AND 

RATING. DISCONNECT SUPPLY CORD BEFORE CHANGEING 
FUSE.

WARNING :

  TO REDUCE THE RISK OF FIRE OR 

ELECTIRC SHOCK. DO NOT EXPOSE THIS EQUIPMENT TO 
RAIN OR MOISTURE.  DO TNO REMOVE COVER. NO USER 
SERVICEABLE PARTS INSIDE. REFER SERVICING TO 
QUALIFIED PERSONNEL.

CAUTION -

 HOT SURFACE AVOID CONTACT

MADE IN KOREA

SERIAL

NUMBER

XP-1450

Powered Mixer

XP-Series

2+v1 Outs

®

POWER

ON

OFF

CAUTION :

 

EXTERNAL SPEAKER

LOAD IMP. MINUM 4

 

Ω

CHANNEL - 2

Parallel

( 300W / 4 Ohm)

(Above 4Ω) 

Speaker Connection

CHANNEL - 1

Parallel

( 300W / 4 Ohm)

(Above 4Ω) 

PRIMARY FUSE

T4.0A / 250V

230V 50Hz, 660W

POWER INPUT

CAUTION:

 

TO REDUCE 

THE RISK OF FIRE REPLACE 

WITH SAME TYPE.

Pin 2

Pin 1

1+

2-(NC)

1-

2+(NC)

PRIMARY FUSE

T8.0A / 250V

230V 50Hz, 1200W

POWER INPUT

CAUTION :

 

EXTERNAL SPEAKER

LOAD IMP. MINUM 4

 

Ω

POWER

ON

OFF

CHANNEL - 1

Parallel

( 350W / 4 Ohm)

(Above 4Ω) 

CHANNEL - 2

Parallel

( 350W / 4 Ohm)

(Above 4Ω) 

CHANNEL - 3

Parallel

( 350W / 4 Ohm)

(Above 4Ω) 

Speaker Connection

XP-1750C

Powered Mixer

XP-Series

3+1 Outs

MADE IN KOREA

SERIAL

NUMBER

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION !!

CAUTION :

  REPLACE WITH SAMETYPE FUSE AND 

RATING. DISCONNECT SUPPLY CORD BEFORE CHANGEING 
FUSE.

WARNING :

  TO REDUCE THE RISK OF FIRE OR 

ELECTIRC SHOCK. DO NOT EXPOSE THIS EQUIPMENT TO 
RAIN OR MOISTURE.  DO TNO REMOVE COVER. NO USER 
SERVICEABLE PARTS INSIDE. REFER SERVICING TO 
QUALIFIED PERSONNEL.

CAUTION -

 HOT SURFACE AVOID CONTACT

®

CAUTION:

 

TO REDUCE 

THE RISK OF FIRE REPLACE 

WITH SAME TYPE.

Pin 2

Pin 1

1+

2-(NC)

1-

2+(NC)

5

5

4

4

1

1

2

2

3

3

▒ REAR PARTS-1/2

(Rear Section) XP-1750C/2050C

(Rear Section) XP-1450

1. POWER SWITCH

 Mains switch to turn the XP on or off. Please make sure to set the master faders to their minimum position before 
switching the power on. This will save you, your audience, and the equipment from unnecessary stress. In case 
additional external equipment is connected to the XP - e.g. power amps, FX units, EQs, etc. - please, proceed in 
the following order when switching your equipment on:
1. switch on the FX units, 
2. switch on the XP
3. switch on external power amps
When switching the power off, please proceed in the opposite order.

XP-Series 10

Summary of Contents for XP-1450

Page 1: ...u m e C o n t r o l 0 10 MON MID HIGH 1 LOW HI Z LO Z HI 12KHz dB dB 15 15 M o n i t o r C o n t r o l 0 10 5 0 10 Eff e c t C o n t r o l 0 10 MID 2 5KHz dB dB 15 15 LOW 80Hz dB dB 15 15 GAIN VOL LIN...

Page 2: ...XP Series 15...

Page 3: ...when left unused for extended periods of time Cleaning The appliances should be cleaned only as recommended by the manufacturer Debris and Liquid Entry Care should be taken that debris and or liquids...

Page 4: ...external amplifier which pow ers your monitor speakers via the MONITOR LINE OUT jack Each channel s monitor send signal is controlled by the channel s MON knob The monitor signal is for pre VOLUME so...

Page 5: ...uivalent to a channel fader 6 LINE INPUT LINE Line input connects standard 1 4 plug unbalanced line other than microphone signals it receives all other kinds of signals from sources like keyboard elec...

Page 6: ...ck volume Caution Please reduce this volume to a minimum to prevent noise and trouble when recording in MP3 10 MP3 TAPE CD SELECT SWITCH This is a switch that select a device to use Each time the swit...

Page 7: ...AT CONTROL DELAY ECHO REAPEAT CONTROL adjust the number of iteration 7 DELAY LEVEL CONTROL DELAY ECHO LEVEL CONTROL adjust the volume of the sound effect Raising too much volume for this effect howlin...

Page 8: ...10 ERED MIXER HEADPHONE HEADPHONE XP 1750C 2050C XP 1450 7 8 9 1 3 4 5 6 2 Master Section Master Monitor Section 1 OUTPUT VU METER Indicator for the displaying of operating status and the output volum...

Page 9: ...ise and trouble when recording 5 PLAY PAUSE BUTTON Using this button you can play or stop the MP3 File 6 RECORD BUTTON Recording is started when this button is pressed in the stop mode and the recordi...

Page 10: ...r Connection XP 1750C Powered Mixer XP Series 3 1 Outs MADE IN KOREA SERIAL NUMBER RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION CAUTION REPLACE WITH SAMETYPE FUSE AND RATING DISCONNECT SUPPLY CORD BEFOR...

Page 11: ...nual when establishing speaker connections HINT Using passive subwoofers that add the input signal of the left and right channel is not possible for techni cal reasons XP Series Cable Application MIC...

Page 12: ...80dB Below A Weight filter TONE CONTROL MIC CH TONE CONTROL LOW 80Hz 15dB MID 2 5KHz 15dB HIGH 12KHz 15dB MASTER CH TONE CONTROL LOW 80Hz 15dB MID 2 5KHz 15dB HIGH 12KHz 15dB LEVEL INDICATOR VU Meter...

Page 13: ...XP Series 13...

Page 14: ...XP Series 14...

Page 15: ...XP Series 15...

Page 16: ...1 3 1 3 15dB 12kHz Shelving 15dB 2 5kHz Shelving 15dB 80Hz Shelving 2 MON MONITOR LINE OUT MON XP Series 16...

Page 17: ...MON 15 db 3 EFF EFF LEVEL EFF 10 db 32 XP Series 17...

Page 18: ...2 3 4 TRIM GAIN MIC LINE GAIN XLR MIC 20 db 50 db MIC LINE TRIM 5 VOL 20 db 6 LINE LINE LINE 1 4 7 MIC MIC XLR 0 02 XP Series 18...

Page 19: ...3 3 CD 8 MUTE MIC EFF MON MUTE MIC EFF MON Mono Mono TS 1 4 9 CD MP3 MP3 10 CD MP3 CD MP3 11 CD RCA RCA RCA TAPE IN LEVEL XP Series 19...

Page 20: ...1 2 3 4 5 6 7 8 9 10 ST MONO 11 Foot S W XP Series 20...

Page 21: ...1 2 LED 3 XP 1750C 2050C 4 XP 1750C 2050C 5 XP 1750C 2050C 6 XP 1750C 2050C MASTER 1 s VUMETER XP Series 21...

Page 22: ...7 8 9 XP Series 22...

Page 23: ...MP3 USB SD MP3 1 USB USB 2 SD SD 3 IR MP3 Player 12 15 4 MP3 Player MP3 TAPE 5 MP3 6 00 01 FILE XXX FILE RECORD LINEIN FILE XXX 7 MP3 Player 8 9 10 2 11 USB SD XP Series 23...

Page 24: ...1 2 XP 1750C 2050C XP 1450 1 XP FX XP 1 FX 2 XP 3 XP Series 24...

Page 25: ...2 2 5 XP 4 2 5 XP XP XLR XLR XLR XLR XP Series 25...

Page 26: ...r NOISE 80dB Below A Weight filter TONE CONTROL MIC CH TONE CONTROL LOW 80Hz 15dB MID 2 5KHz 15dB HIGH 12KHz 15dB MASTER CH TONE CONTROL LOW 80Hz 15dB MID 2 5KHz 15dB HIGH 12KHz 15dB LEVEL INDICATOR V...

Page 27: ...XP Series 13 MEMO 1 XP Series 27...

Reviews: