background image

I N S T R U C T I O N

 © 2014 OJ Electronics A/S

1

67264 04/14 - (LOA)

Type MSW4-10

English

MSW4 is a gateway between the Comfort 

System4™ and a WiFi router. 

The Gateway 

features a graphical user interface,

 

allowing you 

to remote controll the functions of the Central 

Controller in the heating system, 

CS4

TM

.  

Wireless communication with the Central Con-

troller ensures simple installation. 

The Gateway is for wall mounting close to the 

router.  

NOTE: The Gateway requires a Central Con-

troller with software version 1.12 or newer. 

PrOduCT PrOGraMME

MSW4-10:  Ethernet Gateway to remote control 

the heating system, CS4

TM

 

WarNING

 – Important safety instructions  

Never attempt to open the Gateway

.  

Disconnect the power supply before perform-

ing installation or maintenance work on the unit 

or its associated components. This control unit 

and its associated components can be installed 

by anyone. Electrical installation must be in ac-

cordance with relevant regulations. 

INSTallING ThE GaTEWay

dO NOT open

 the Gateway. 

1. Mount the Gateway on the wall.  

There are “keyholes” on the rear of the hous-

ing for screws – see the drilling template 

below for details. 

2. Distance between the wall and the rear face 

of the screw head should be 3.5 mm.

3.  Connect the cables as shown in the wiring 

diagram (fig. 1).

SETuP

1. Make sure the Central Controller is in “listen-

ing mode” (Press Menu/System settings/Add 

unit).

2. Switch on the power to the Gateway.

3. “Con” flashes on the Gateway.

4. “Adr/99” flashes. 

The Central Controller and 

the Gateway will display the assigned a

d-

dress. Must be 99.

5. “LAn” and the arriel symbol is displayed in 

the Gateway; Communication ok.

6. Readout the IP-address for the Gateway 

(

IP

1

. IP

2

. IP

3

. IP

), by pressing the navigation 

buttons.

7. The Gateway is now ready to use via the 

web-server. Set the server to search for the 

IP-address of the Gateway.

(See the User Manual for further information).

ErrOr COdES

If a error occurs, the Gateway will display an 

error code as follows:

Con:  Searching for connection to the Central 

Controller. 

OFL:  No connection to the network router.

Err:  The Central Controller does not support 

the Gateway (Software version too old). 

E6:     Communication error. No connection to 

the Central Controller. 

CE MarKING

According to the following directives: 

LVD 2006/95/EC, EMC 2004/108/EC, 

R&TTE 1999/5/EC.

ClaSSIfICaTION

The product is a Class II device (double insu-

lated) and must be connected in the following 

way: 

Input: Power supply.

Ethernet (RJ45): For connection to router. Cable 

length must not exceed 3 metres. (See fig. 1).

ENvIrONMENT aNd rECyClING

Please help us to protect the environment by 

disposing of the packaging in accordance with 

the national regulations for waste processing.

rECyClING Of ObSOlETE aPPlIaNCES

Appliances with this label must not 

be disposed of with general 

household waste. They must be 

collected separately and disposed 

of in compliance with local 

regulations.

 

TEChNICal daTa 

Gateway:

Supply voltage  ........................................  9 VDC

Standby power .........................................  2.3 W

RF frequency band ............................ 868.3 MHz

RF-Transmission range..... 100 metres/open field 

Ambient temperature ............................. 0/+40°C

Pollution degree ................................................ 2

Enclosure rating ........................................ IP 20*

Dimensions .....................  H/84, W/84, D/58 mm

Display ...................... H/25, W/38 mm, segment

EU registered design  .......... 001534462-0001/2

to EN 60730-2-9

*  IP 20 applies only to the complete product 

after mounting on wall. 

Power unit:

Supply voltage .................230 VAC ±10%, 50 Hz

Output voltage .............................9 VDC nominel 

DC switch  .......................2.0 mm centre hole (+)  

and 5.5 mm shell (-)

Overvoltage ................................................ Cat II

Current .................................................... 500 mA

Network cable (rJ-45)

Category .................................................... Cat. 5

Length ....................................................... 0.5 m

Max. network cable length ............................3 m

The Gateway is maintenance free. 

OJ ElECTrONICS a/S

Stenager 13B · DK-6400 Sønderborg

Tel: +45 73 12 13 14 · Fax: +45 73 12 13 13

[email protected] · www.ojelectronics.com

33 mm

Ø 4.8 mm

32 mm

65 mm

29.25 mm

20 mm

49.25 mm

Ø 9 mm

Ø 9 mm