8 (24)
GT02 1408 EN
Control panel buttons
1 Domestic hot water
6 OK
2 Heating mode
7 Cooling
3 Information
8 Reset
4 Back/ESC
9 Occupancy button
5 Settings knob
Domestic hot
water button
When this function is on, the heat pump generates domestic hot
water automatically according to set settings. When the function is
off, the heat pump does not generate any domestic hot water.
Pressing and holding the button for five seconds or longer activates
forced charging. In forced charging the domestic hot water is
heated to its nominal setpoint even the temperature of the domestic
hot water is not yet below the charging temperature.
Heating
mode button
Press the button to select a heating mode. A black bar is displayed
beneath the symbol of the selected heating mode. To toggle
between the various modes, press the button repeatedly.
The heating modes are:
Cooling (not in use)
Automatic mode
The heat pump switches heating between the comfort
setpoint and the reduced setpoint automatically,
according to a time program.
Comfort setpoint
Reduced setpoint
Frost protection temperature
Information
button
Press the information button to display the heat pump status and
error notifications on the display panel. You can browse through
data and notifications one item at a time by pressing the information
button again, or you can turn the settings knob left or right to
browse through the items.
Back/ESC button Use the back/ESC button to exit settings or menus. If you have
changed a setting, but wish to cancel the change, you can press the
back button to exit the setting without saving any change.
Settings knob Use the selection knob to browse through menus and to change
settings. You can turn the selection dial clockwise or anti-clockwise.
OK button
Press the OK button to enter a menu that you have selected or to
commit changes.