Precautions
WARNING
●
Do not put through the power before finishing installation.
●
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
●
The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper
tube.
●
The appliance shall be installed in accordance with
national wiring regulations.
●
Installation must be performed in accordance with the
requirement of NEC and CEC by authorized personnel
only.
●
The air conditioner is the first class electric appliance. It
must be properly grounding with specialized grounding
device by a professional. Please make sure it is always
grounded effectively, otherwise it may cause electric shock.
●
The yellow-green wire in air conditioner is grounding
wire, which can't be used for other purposes.
●
The grounding resistance should comply with national
electric safety regulations.
●
The appliance must be positioned so that the plug is
accessible.
●
All wires of indoor unit and outdoor unit should be
connected by a professional.
●
If the length of power connection wire is insufficient, please
contact the supplier for a new one. Avoid extending the
wire by yourself.
5
Precautions
WARNING
●
For the air conditioner with plug, the plug should be
reachable after finishing installation.
●
For the air conditioner without plug, an circuit break
must be installed in the line.
●
If you need to relocate the air conditioner to another
place, only the qualified person can perform the work.
Otherwise, it may cause personal injury or damage.
●
Select a location which is out of reach for children and
far away from animals or plants.If it is unavoidable,
please add the fence for safety purpose.
●
The indoor unit should be installed close to the wall.
●
Instructions for installation and use of this product are
provided by the manufacturer.
Working temperature range
Indoor side D
B/WB(°C)
Maximum cooling
Outdoor side DB/WB(
°C)
32/23
43/26
Maximum heating
27/-
24/18
Indoor side D
B/WB(°C)
Maximum cooling
Outdoor side DB/WB(
°C)
32/23
52/32
Maximum heating
27/-
24/18
NOTICE:
For some models:
● The operating temperature range (outdoor temperature) for Low-temperature
cooling only unit is -15
°C
~ 43
°C
; for Low-temperature heat pump unit is
-22
°C
~ 43
°C
.
For model:GWH24AAE-K6DNA4Z
● The operating temperature range (outd
o
or temperature) for cooling only unit is
-15°C
~ 43
°C
; for heat pump unit is -15
°C
~ 43
°C
.
For models:GWH18YE-S6DBA2A, GWH24YE-S6DBA2A,
GWH09ACC-S6DBA1A, GWH12ACC-S6DBA1A, GWH18ACE-S6DBA1A
NOTICE:
● The operating temperature range (outdoor temperature) for cooling only unit is
-18°C
~ 52
°C
; for Low-temperature heat pump unit is -30
°C
~ 52
°C
.
6