- 10 -
SYMPTOM
CAUSE
CORRECTIVE ACTION
A green lamp blinks while in
use by automatic mode.
・
There are no screws in the
Nejikura hopper.
・
A screw is caught on the way.
・
Automatic screw feeder not
working.
・
Fill Nejikura with screws.
・
Check that the screws are not caught on the
rotating drum.
・
If the sensor does not change even if the
drum rotates three times, the operation stops
once to prevent overfilling. When the automatic
screw feeder operates and the sensor changes,
it resumes operation.
The machine does not supply
screws even if the number of
screws in the automatic screw
feeder is low.
・
Auto switch is off (LED lamp is
off)
・
The screw detection sensor is
dirty.
・
The screw detection sensor
adjustment is incorrect.
・
Turn on the Auto switch (LED lamp lights).
・
Clean the sensor.
・
Make the adjustment referring to 5-1.
The supply does not stop even
though there is an appropriate
amount of screws in the auto-
matic screw feeder.
・
The screw detection sensor is
dirty.
・
The screw detection sensor
adjustment is incorrect.
・
Clean the sensor.
・
Make the adjustment referring to 5-1.
The motor is rotating, but the
rotating drum is not rotating.
・
The drive belt is damaged.
・
Contact your dealer.