Summary of Contents for UPM-DT-50SP

Page 1: ...DIGITAL ULTRASOUND WATTMETER UPM DT 50SP USER MANUAL...

Page 2: ......

Page 3: ...12 SPECIFICATIONS 13 NOTES 14 UPM DT 50SP ULTRASOUND WATTMETER TABLE OF CONTENTS WARNING USERS The UPM DT 50SP is for use by skilled technical personnel only CALIBRATION INTERVAL To ensure the accurac...

Page 4: ...is intended for use within the published specifications Any application beyond these specifications or any unauthorized user modifications may result in hazards or improper operation CAUTION INSPECTIO...

Page 5: ...s PPM Parts Per Million Lbs pounds USA United States of America V Volt s VAC Volt s Alternating Current VDC Volt s Direct Current W Watt s CAUTION LIQUIDS Do not submerge or spill liquids on the UPM D...

Page 6: ...DISCLAIMER OHMIC INSTRUMENTS RESERVES THE RIGHT TO MAKE CHANGES TO ITS PRODUCTS OR SPECIFICATIONS AT ANY TIME WITHOUT NOTICE IN ORDER TO IMPROVE THE DESIGN OR PERFORMANCE AND TO SUPPLY THE BEST POSSIB...

Page 7: ...c energy passes through the water to reflect off the target and is then absorbed by the rubber lining The radiant power is directly proportional to the total downward force weight on the target This f...

Page 8: ...f air To degas boil distilled water for 30 minutes then seal the container tightly and place it in a refrigerator An alternate method of degassing water is to heat the water to the boiling point then...

Page 9: ...for conical target assembly details Remove the wetted conical target then lower the conical target support stem into the target support tube located behind the test tank while simultaneously placing t...

Page 10: ...4 Figure 2 Conical Target Installation Target Support Stem of Conical Target Assembly Target Support Tube UPM DT 50SP Test Tank...

Page 11: ...t gently wipe the surface clean using your finger Position the transducer head so it is directly facing the center of the conical target and submerged 1 8 to 1 4 in the degassed water Tighten the two...

Page 12: ...6 Figure 4 Transducer Placement Details Transducer Head Submerged and Positioned Directly Over the Conical Target Transducer Handle Firmly Clamped in Position Conical Target Assembly Installed...

Page 13: ...t is displayed g grams c custom Watts 3 Function Mode Button Press and hold to toggle measurement modes Always use Weigh Mode 4 Tare Menu Button Press to Tare the weight of the Conical Target Assembly...

Page 14: ...8 Back Bottom Power Input Receptacle 5VDC 1 A Communications Print Port Battery Compartment 4 AA Batteries...

Page 15: ...ndard Weight 6 Select the desired test measurement unit Allow the UPM DT 50SP and tank water to stabilize With no ultrasonic power applied press the Tare button to Net zero the meter 7 Test the DUT av...

Page 16: ...om Watts mode An unstable reading is indicated by a at the end of the print line i e 0 000 g Communication Commands RS232 Communication Interface Baud Rate 9600 8 Bit Data No Parity No Handshake Note...

Page 17: ...ir Refill with fresh degassed water Contact Ohmic Instruments for Calibration and or Repair After zeroing taring the measurement continually drifts with no transducer power applied The meter does not...

Page 18: ...WARRANTY EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OHMIC INSTRUMENTS IS NOT LIABLE FOR ANY INCIDENTAL OR CONSEQUENT...

Page 19: ...ed Water 24 0 3 0 C 75 2 5 4 F ELECTRICAL BATTERY Quantity 4 AA IEC LR6 Alkaline BATTERY ELIMINATOR 5 VDC 1 A PHYSICAL ENVIRONMENTAL DISPLAY 6 digit Backlit LCD CONSTRUCTION TANK LINING 0 25 Inch 6 35...

Page 20: ...13 NOTES...

Page 21: ...14 NOTES...

Page 22: ...15 NOTES...

Page 23: ......

Page 24: ...IC INSTRUMENTS 3081 ELM POINT INDUSTRIAL DRIVE ST CHARLES MO 63301 USA 410 820 5111 www ohmicinstruments com sales ohmicinstruments com UPM DT 50SP User Manual 08 17 Rev 01 Copyright 2017 Made in the...