background image

EN-22                                   

       

Ranger™ 2000

 

Series

 

 

4.7 Unit Menu  

This menu activates units so they will be accessible with the 

Units

 button. The units 

in the menu m

ust be turned “on” to be active.  

Note: Available units vary by model and local regulations.

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Ranger R21PE1502

Page 1: ...Ranger 2000 Series Instruction Manual...

Page 2: ......

Page 3: ...oved accessories and peripherals Operate the scale only under ambient conditions specified in these instructions Disconnect the scale from the power supply when cleaning Do not operate the scale in ha...

Page 4: ...in a small round window on the front of the scale To level the scale adjust the feet so the bubble is centered in the circle Be sure the equipment is level each time its location is changed Figure 2 2...

Page 5: ...symbol see item 9 in table 3 2 indicates the battery charging status When charging the symbol will blink slowly and when fully charged the symbol will be turned off TABLE 2 2 Symbol Charge level Batt...

Page 6: ...oggles through active weighing units Short Press in Menu Toggles through available settings Function Mode Back Short Press Selects function setting Long Press Selects active mode Short Press in Menu R...

Page 7: ...ol 2 Center of Zero symbol 9 Battery charge symbol 3 Negative symbol 10 Pound Ounce Pound Ounce symbols 4 Stable weight symbol 11 Kilogram gram symbols 5 Preset Tare Tare symbols 12 Pieces symbol 6 Po...

Page 8: ...Yellow Loads Lower limit Figure 3 4 Below view of Ranger 2000 3 2 Turning Scale On Off To turn the scale on press and hold the On Zero Off button for 1 second The scale performs a display test moment...

Page 9: ...rence weight The display shows 100 6 Replace the reference material with the sample material The display shows the percentage of the sample compared to reference weight 7 To clear the stored reference...

Page 10: ...and highlight the next digit Repeat until all the digits are correct Press Yes to accept the low limit value Set Hi will be displayed 4 Repeat the same procedure to accept or edit the high value 5 If...

Page 11: ...ngs please see section 4 2 for details 3 6 3 Check Count Set Checkweigh to Count in the Mode menu Use this mode to compare the quantity of items to a target quantity range 1 Press and hold Mode until...

Page 12: ...imit Place the item to be weighed on the scale and press TARE Remove a portion of the item until it is within the ACCEPT range Zero Check Zero check is used when comparing subsequent samples to an ini...

Page 13: ...y pressing the Function key rEAdY Ready will then be displayed Note If Set0 has been selected the countdown timer is not displayed The first weight larger than 5d will be displayed and held Automatic...

Page 14: ...removed With ACCUMULATE set to AUTO place the item on the scale The displayed value is accumulated automatically The icon will keep flashing until the weight is removed 3 8 2 Viewing and Clearing Sta...

Page 15: ...Put the weight 0 04 kg on the pan and press M key The icon indicator will keep flashing until the weight is removed Step ii Remove the weight from the pan Put another weight 0 03 kg and press M key S...

Page 16: ...w opening Install the hook accessory into the access hole at the bottom of the scale as shown Do not over tighten tighten finger tight Mount the scale onto an appropriate assembly that allows free wor...

Page 17: ...End U n i t P r i n t C O M L O C k E n d Menu Items Reset kg g lb oz lb oz End Reset Stable A Print Contnt Layout Data Tr End Reset Baud Parity Stop Handsh Alt Cm End L Cal L Setup L Read L Mode L Un...

Page 18: ...mits the current setting is displayed with all digits flashing Press the No button to begin editing The first digit is displayed flashing Press the No button to increment the digit or press the Yes bu...

Page 19: ...an Press Yes to accept the weight or No to select an alternate weight C will be displayed while the reading is stored The display will show done if the calibration was successful The scale returns to...

Page 20: ...are is disabled ON the first stable gross weight is tared ON ACC stable gross loads within the accept limits are tared in Check weighing mode Beeper Signal Bp sIG Set how the beeper responds in Check...

Page 21: ...to factory defaults NO not reset YES reset Stable Range Stable Set the amount the reading can vary while the stability symbol remains on 0 5d 0 5 scale division 1d 1 scale division 2d 2 scale divisio...

Page 22: ...been exceeded Light LIGHt Set the light intensity LO low light intensity MED medium light intensity HI high light intensity Sleep SLEEP Set the display shut off time OFF disabled display will stay on...

Page 23: ...ON enabled Check CHECk Set the sub mode OFF disabled WEIGH weight mode PERCNT percent mode COUNT count mode Dynamic DYNAmM Set the status OFF disabled MAN averaging and resetting are initiated manual...

Page 24: ...2000 Series 4 7 Unit Menu This menu activates units so they will be accessible with the Units button The units in the menu must be turned on to be active Note Available units vary by model and local...

Page 25: ...each time the display is within the Checkweigh accept range and stability criteria are met CONT printing occurs continuously When ON STAB is selected set the condition for printing where LOAD printing...

Page 26: ...e status OFF disabled ON the Tare weight is printed Header Set the status OFF disabled ON the Header is printed Note See section 7 3 1 for instructions how to enter Header line Footer Set the status O...

Page 27: ...tart Menu in Windows XP and click Settings open Control Panel 2 Double click Accessibility Options in Control Panel 3 Select the General tab 4 Check Use Serial Keys and click the Settings button 5 Sel...

Page 28: ...aritY Set the data bits and parity 7 EVEN 7 data bits even parity 7 ODD 7 data bits odd parity 7 NONE 7 data bits no parity 8 NONE 8 data bits no parity Stop bit stOP Set the number of stop bits 1 1 s...

Page 29: ...e Print Tare and Zero commands Print Set the alternate command character for Print A to Z Tare Set the alternate command character for Tare A to Z Zero Set the alternate command character for Zero A t...

Page 30: ...tup menu is not locked ON Setup menu is locked Lock Read l rEAD Set the status OFF Readout menu is not locked ON Readout menu is locked Lock Mode l mMod Set the status OFF Mode menu is not locked ON M...

Page 31: ...OFF COM menu is not locked ON COM menu is locked End Lock End Advance to the next menu or return to the top of the current menu 4 11 End Menu Press Yes to exit the menu and return to the current appli...

Page 32: ...1 42 19 43 26 17 16 16 15 15 14 14 13 13 12 12 43 26 44 32 17 17 16 16 15 15 14 14 13 13 12 44 32 45 38 18 17 17 16 16 15 15 14 14 13 13 45 38 46 45 18 18 17 17 16 16 15 15 14 14 13 46 45 47 51 19 18...

Page 33: ...le Zero Range setting is locked at 2 Stable Range setting is locked at 1d Auto Zero Tracking setting is locked at 0 5d Units are locked at their current settings Stable Only is locked On Auto Print Co...

Page 34: ...charge the battery Err 8 1 Power On Error Weight reading exceeds Power On Zero limit Err 8 2 Power On Error Weight reading below Power On Zero limit Err 8 3 Over Range Error Weight reading exceeds Ov...

Page 35: ...chnical support in the United States call toll free 1 800 526 0659 between 8 00 AM and 5 00 PM EST An OHAUS product service specialist will be available to provide assistance Outside the USA please vi...

Page 36: ...05 lb 240oz x 0 01oz 15kg x 0 0005kg 15000g x 0 5g 30 lb x 0 001 lb 480oz x 0 02oz 30kg x 0 001kg 30000g x 1g 60 lb x 0 002 lb 960oz x 0 04oz 30 kg x 0 0001kg 30000g x 0 1g 60 lb x 0 0002 lb 960oz x 0...

Page 37: ...Ranger 2000 Series EN 35 7 2 Drawings Figure 7 1 Dimensions 311 mm 12 2 in 327 mm 12 9 in 117 mm 4 6 in...

Page 38: ...o print OFF Z Same as pressing Zero Key T Same as pressing Tare Key xT Download Tare value in grams positive values only Sending 0T clears tare if allowed PU Print current unit g kg lb oz lb oz t c cu...

Page 39: ...on line If Printx Content Info is ON MODE WEIGH Mode line If Printx Content Application Mode is ON Into is ON Weigh Mode with Accumulation Printout Description Comment 12 34 kg Result line If Printx C...

Page 40: ...entered 11 11 kg N Net value line If Printx Content Net is ON and a tare value is entered 1 23 kg T Tare value line If Printx Content Tare is ON and a tare value is entered MODE COUNT Mode line If Pr...

Page 41: ...ght aligned Space Application Status Right aligned Term Length 11 1 5 1 1 1 2 1 6 2 Non Check Weighing application Field Weight Right aligned Space Unit Right aligned Space Stability Space T N G PT Ri...

Page 42: ...been damaged by accident or misuse exposed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other than...

Page 43: ......

Page 44: ...Avec des bureaux dans le monde entier Weltweite Gesh ftsstellen Con uffici in tutto il mondo www ohaus com 30037458 P N 30037458D 2017 OHAUS Corporation all rights reserved todos los derechos reservad...

Reviews: