EN-4 

 

  

3. CONNECTING THE INTERFACE 

The PJX balance has two connectivities, RS232 port and Mini DIN. 
Use the RS-232 port to connect either to a computer or a printer with a standard (straight-through) serial cable.  
 
Mini DIN is used to connect with another accessory, as an alternative option for RS232. 
 

Interface connections on the rear of the balance 

                            

 

 

 

 

RS232: Used to connect to PC or Printer 

4. MAINTENANCE 

4.1 Cleaning 

 

Please  disconnect  the  balance  from  the  power  supply  before  cleaning.  Make  sure  that  no 
liquid enters the interior of the balance. 

 

Clean the balance at regular intervals. Housing surfaces may be cleaned with a lint-free cloth slightly dampened 
with water or a mild cleaning agent.  Glass surfaces may be cleaned with a commercial glass cleaner.    

Attention:

 

Do not use solvents, harsh chemicals, ammonia or abrasive cleaning agents. 

4.2 Troubleshooting  

 

Symptom / Display 

Possible Cause 

Err 8.1 

Weight reading exceeds Power On Zero limit.

 

Err 8.2 

Weight reading below Power On Zero limit. 

Err 8.3 

Weight reading exceeds overload limit. 

Err 8.4 

Weight reading below underload limit. 

Ref Err 

Reference Weight too small.  The weight on the pan is too small to define a valid 
reference weight. Add additional samples. 

LowW.rEF

 

A warning that the reference weight is below the recommended value for accurate 
parts  counting.  Add  additional  samples  if  possible  otherwise  counting  continues 
with diminished accuracy. 

------- 

Busy (tare, zero, and printing). 

--

NO

-- 

Function not executed. 

Error 

Timeout 

IDnr.Err 

IDNR Error 

5. USER MANUAL 

Please read instruction manual before you use the balance, you can find it at OHAUS website, 

www.ohaus.com 

 

RS232 

Mini DIN 

Summary of Contents for Pioneer PJX Series

Page 1: ...PJX Series Balances Quick Start Guide Quick_Start_Guide_PJX_V1 ...

Page 2: ......

Page 3: ...low sufficient space 1 2 Leveling Be sure the balance is level before it is used or after its location is changed The PJX balance has a level bubble in a small round window beside the display To level the balance adjust the 4 leveling feet until the bubble is centered in the circle Please refer to the below figure for leveling ...

Page 4: ... Display Button Primary Function Short Press On Zero If the balance is Off turns on the balance If balance is On sets zero Print Sends the current displayed value to the serial interface Function Operation is dependent on the application mode Tare Performs tare operation Secondary Function Long Press Off Zeroing current value Unit Changes weighing units Mode Changes application mode Menu Cal Enter...

Page 5: ...ess No until SpaN span calibration is displayed 4 The Calibration mass value will be shown in the screen After the display shows 200 0000 g place weight s of 200 g on the pan for calibration To change to the calibration point of half full capacity e g 100 g press the Function Mode button After the screen shows Place weights and 100 0000 g place weight s of 100 g on the pan for calibration 5 Once t...

Page 6: ... cleaned with a commercial glass cleaner Attention Do not use solvents harsh chemicals ammonia or abrasive cleaning agents 4 2 Troubleshooting Symptom Display Possible Cause Err 8 1 Weight reading exceeds Power On Zero limit Err 8 2 Weight reading below Power On Zero limit Err 8 3 Weight reading exceeds overload limit Err 8 4 Weight reading below underload limit Ref Err Reference Weight too small ...

Page 7: ......

Page 8: ...us Corporation 7 Campus Drive Suite 310 Parsippany NJ 07054 USA Tel 1 973 377 9000 Fax 1 973 944 7177 With offices worldwide www ohaus com 30469440 P N 30469440 A 2018 Ohaus Corporation all rights reserved ...

Reviews: