OHAUS Courier 1000 Instruction Manual Download Page 15

Courier 1000 

 

EN-11 

FCC Supplier Declaration of Conformity 

Unintentional Radiator per 47CFR Part B 

 

Trade Name: OHAUS CORPORATION 

Model: i-C12Pxxx 

 

Party issuing Supplier’s Declaration of Conformity: 

Ohaus Instruments (Changzhou) Co., Ltd. 

Building C, No. 6 Zhengqiang Road, Xuejia Town, Xinbei District, Changzhou 

Jiangsu 213022, 

China 

Phone: +86 519 85287270 

 

Responsible Party – U.S. Contact Information: 

Ohaus Corporation  

8 Campus Drive, Suite 105 

Parsippany, NJ 07054  

United States  

Phone: +1 973 377 9000 

Web: www.ohaus.com 

 

FCC Compliance Statement: 

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant 

to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 

interference when the equipment is operated in a commercial environment. This equipment generates, uses, 

and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, 

may cause harmful interference to radio communications. Operation of this equipment in a residential area is 

likely to cause harmful interference in which case the user will be required to correct the interference at his own 

expense. 

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s 

authority to operate the equipment. 

 

LIMITED WARRANTY

 

OHAUS products are warranted against defects in materials and workmanship from the date of delivery through 
the duration of the warranty period. During the warranty period OHAUS will repair, or, at its option, replace any 
component(s) that proves to be defective at no charge, provided that the product is returned, freight prepaid, to 
OHAUS.  This warranty does not apply if the product has been damaged by accident or misuse, exposed to 
radioactive or corrosive materials, has foreign material penetrating to the inside of the product, or as a result of 
service or modification by other than OHAUS. In lieu of a properly returned warranty registration card, the 
warranty period shall begin on the date of shipment to the authorized dealer. No other express or implied 
warranty is given by OHAUS Corporation. OHAUS Corporation shall not be liable for any consequential 
damages.  
 
As warranty legislation differs from state to state and country to country, please contact OHAUS or your local 

OHAUS dealer for further details 

 

 

Summary of Contents for Courier 1000

Page 1: ...Courier 1000 Instruction Manual ...

Page 2: ......

Page 3: ...REVISION HISTORY Date Version Description February 6 2023 A New manual ...

Page 4: ......

Page 5: ...pter Power 4 2 3 2 Battery Power 4 3 OPERATION 5 3 1 Turning On Off the Scale 5 3 2 Zero Operation 5 3 3 Changing the Units of Measure 5 3 4 Auto Shut Off 5 3 5 Dynamic Weighing 5 3 6 Weight AlertTM 5 4 CALIBRATION 6 4 1 Span Calibration 6 4 2 Calibration Locking 7 5 MAINTENANCE 8 5 1 Cleaning 8 5 2 Troubleshooting 8 5 3 Service Information 8 6 TECHNICAL DATA 9 6 1 Specifications 9 6 2 Drawings an...

Page 6: ...hat it is difficult to reach the power connection Make sure that the power cord does not pose a potential obstacle or tripping hazard Operate the equipment only under ambient conditions specified in these instructions The equipment is for indoor use only Do not operate the equipment in wet hazardous or unstable environments Do not allow liquids to enter the equipment Do not load the equipment abov...

Page 7: ...t side of the display indicates a low battery condition When first displayed approximately 12 hours of operation remain When the battery is fully depleted the scale will momentarily display Lo bAt and shut off 2 Large 7 Segment Numeric Characters Weight mass values are shown using 4 digits including negative sign and decimal places Prompts for calibration and possible error conditions are also sho...

Page 8: ...available Connect the AC adapter plug to the input jack Then plug the AC adapter into a properly grounded power outlet Figure 2 1 Power Connection 2 3 2 Battery Power Open the battery cover on the bottom of the scale and install 3 x C LR14 batteries into the compartment Orient the batteries as shown on the inside of the compartment Close the battery cover NOTE Batteries are not included in the pac...

Page 9: ...end battery life the scale will automatically turn off after approximately four minutes of inactivity This feature is only active during battery operation 3 5 Dynamic Weighing With the platform empty short press the UNITS Cal button to cycle through the units Dynamic mode is active when the symbol is flashing Place an item on the platform The scale will show A NOTE If using a container press ON ZE...

Page 10: ...t Model Calibration weight kg lb i C12P9 9 20 i C12P20 20 40 i C12P75 50 100 4 1 Span Calibration Span Calibration uses two points to adjust the scale The first point is the zero value where there is no weight on the scale The second point is the Span value where a calibration mass is placed on the scale To select the weighing unit to be used for calibration press the UNITS Cal button until the co...

Page 11: ...screws at the bottom Slide the switch on the PCB marked SW3 to the position marked CAL LOCK Reassemble the cover If required place tamper evident sealing labels over the screw holes or over the housing edges If later recalibration is required the cover will need to be reopened and the lock switch returned to the original position NOTE When the lock switch is set to the CAL LOCK position the power ...

Page 12: ...teries 4 Service required Poor accuracy 1 Improper calibration 2 Unstable environment 1 Perform calibration 2 Move scale to suitable location Unable to calibrate 1 CAL LOCK is set to ON 2 Unstable environment 3 Incorrect calibration mass 1 Set CAL LOCK to OFF 2 Move the scale to suitable location 3 Use correct calibration mass Scale displays Lo bAt Low battery Connect the scale to power outlet Rep...

Page 13: ... 02 lb 75 kg x 0 05 kg 165 lb x 0 1 lb Weighing Units kg lb Modes Weighing Dynamic Weighing Weight AlertTM Weigh AlertTM is only available when lb is activated on i C12P75 model Keypad 2 button mechanical keys Calibration Weights 9 kg 20 lb 20 kg 40 lb 50 kg 100 lb Display 4 digit 7 segment 20mm 0 8 in characters Tare range To capacity by subtraction Stabilization Time 3 seconds Maximum Overload 1...

Page 14: ...rical and Electronic Equipment Regulations 2012 UK Electromagnetic Compatibility Regulations 2016 and Electrical Equipment Safety Regulations 2016 The UK Declaration of Conformity is available online at www ohaus com uk declarations This product complies with the EU Directive 2012 19 EU WEEE Please dispose of this product in accordance with local regulations at the collecting point specified for e...

Page 15: ...e harmful interference in which case the user will be required to correct the interference at his own expense Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment LIMITED WARRANTY OHAUS products are warranted against defects in materials and workmanship from the date of delivery through the duration of the ...

Page 16: ......

Page 17: ...offices worldwide Con oficinas en todo el mundo Avec des bureaux partoutdans le monde MitBürosweltweit Con uffici in tuttoilmondo www ohaus com 30746010 P N 30746010 A 2023 Ohaus Corporation all rights reserved todos los derechos reservados tous droits réservés alle Rechte vorbehalten tutti i diritti riservati ...

Reviews: