     EN-24

               Adventurer Pro

Project ID

Used to enter a Project ID up to 10 characters.

Entering a User ID or Project ID

Enter the user or Project ID one character at a

time.  The character to be entered is highlighted

by a blinking cursor (underscore).  Press the

No

 button repeatedly to scroll through the list

of available characters. ((space), -, 0 through

9, A through Z).  Press the 

Yes

 button to select

the displayed character and move the cursor

one  position  to  the  right.    After  the  tenth

character is entered, the ten character ID will

blink.    Press  the 

No

  button  to  change  the

displayed ID or the 

Yes

 button to accept the ID

and proceed to the next menu item.

Time

Type

Set the type to 12 hours or 24 hours.

Set

Set the current time using the format selected

in the type menu item.

Adjust

Enter an adjustment value from -60 to + 60

seconds per day.

Date

Set the  date type: M/D/Y, D/M/Y, Y/M/D,

M/Y/D, Y/D/M, D/Y/M and the actual date.

End GLP Data

Press the 

Yes

 button to advance to the GLP Print

submenu.  Press the 

No

 button to return to User

ID.

3.7.9 GLP Print

Select GLP items to be printed by setting them

to On.

                

GLP PRINT

Time

On/

Off

Balance ID

On

/Off

User ID

On

/Off

Project ID

On

/Off

Difference

On

/Off

Name

On

/Off

End GLP Prt

RESET

Setup

RESET?

Readout

RESET?

Mode

RESET?

Unit

RESET?

Print-1

RESET?

Print-2

RESET?

RS232-1

RESET?

RS232-2

RESET?

GLP Data

RESET?

GLP Print

RESET?

Lockout

RESET?

Global

RESET?

End Reset

Setup

Select Yes to return all Setup menu items to

their factory settings.

Readout

Select Yes to return all Readout menu items to

their factory settings.

Mode

Select Yes to return all Mode menu items to

their factory settings.

3.7.10

Reset

End GLP Print

Press the 

Yes

 button to advance to the reset

submenu.  Press the 

No 

button to return to Time.

4 Adventurer Pro Text pages 15 to 40.P65

4/10/2003, 6:00 AM

24

All manuals and user guides at all-guides.com

Summary of Contents for Adventurer Pro AV2101

Page 1: ...Adventurer Pro Balances Instruction Manual 1 Adventurer Pro Cover P65 4 10 2003 6 00 AM 1 All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...Directive Standard 73 23 EEC EN61010 1 2001 Electrical equipment for use Safety requirements for electrical within specified voltage limits equipment for measurement control and laboratory use Part 1...

Page 3: ...ass A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada These products also comply with the following standards 315 AS NZS...

Page 4: ...c Operation EN 9 3 3 1 Zeroing EN 9 3 3 2 Taring EN 9 3 3 3 Changing Units of Measure EN 9 3 3 4 Changing Application modes EN 9 3 3 5 Printing Data EN 9 3 4 Menu EN 10 3 4 1 Menu Structure EN 10 3 4...

Page 5: ...to the Balance Settings EN 26 3 10 Printing Data EN 27 4 MAINTENANCE EN 28 4 1 Calibration EN 28 4 2 Cleaning EN 28 4 3 Troubleshooting EN 28 4 4 Error Codes List EN 28 4 5 Service Information EN 29 4...

Page 6: ...Percent Check Weighing Animal and Totalize application modes In use cover RS232 interface Integral security bracket Weigh below hook The Adventurer Pro also offers several optional features Optional U...

Page 7: ...Installing Components Remove the cone cover from the top of the balance and store it for future use Refer to the illustrations below and install the appropriate components 2 3 Selecting the Location L...

Page 8: ...e the button CALIBRATE blinking is displayed Press the Yes button to enter calibration menu Press the Yes button to initiate span calibration Press the Exit button at any time to abort calibration Fir...

Page 9: ...connector 3 Platform 10 COM1 port 4 Type Label 11 Lock release button 5 Data Label 12 Security bracket 6 Battery compartment 13 COM2 port optional 7 Weigh below opening 14 Level Bubble 1 2 3 4 5 6 7...

Page 10: ...tor 13 14 Kilogram indicaton 15 Pennyweight indicator No Description 16 Memory indicator 17 Newton indicator 17 20 Grain indicator 18 Battery charge indicator 19 Pieces indicator 21 Momme Mesghal unit...

Page 11: ...setting on the display Print Sends current display value to the serial interface Unit Change weighing unit No Rejects the current blinking setting on the display Increments a value being entered Funct...

Page 12: ...is cleared automatically when the container is removed from the pan Preset Tare A preset tare value may be entered using the xT command in the command table To clear the Tare value enter a value of 0...

Page 13: ...ata GLP Print Reset Lock Set End Lockout END 3 7 12 3 4 1 Menu Structure PRINT 1 3 7 6 Output When Stable GLP Tare Auto Print Content Num Only Header Gross Net Tare Ref Result GLP Layout Line Format 4...

Page 14: ...isplay Release the button and the first sub menu appears on the secondary display blinking Note A blinking display in the menu indicates a choice must be made using the Yes No or Back buttons SELECT T...

Page 15: ...st be turned on in the Unit menu 3 5 2 Parts Counting Enter this mode to count samples of uniform weight Refer to paragraph 3 3 4 to enable Parts Counting USE The primary display shows COUNT and the s...

Page 16: ...ber of parts The weight is shown on the secondary display Pressing the Function button momentarily displays the APW on the secondary display The example shows an APW of 2 000g 3 5 2 Parts Counting Con...

Page 17: ...hing Enter this mode to compare the weight of a sample against target limits Refer to paragraph 3 4 3 to enable Check Weighing USE The secondary display shows EDIT REF blinking when limits exist Press...

Page 18: ...ER ACCEPT OVER status is shown on the primary display while the actual weight of the item is shown on the secondary display 3 5 4 Check Weighing Cont 3 5 5 Animal Weighing Enter this mode to weigh uns...

Page 19: ...he actual weight and the secondary display alternates between ANIMAL and CLEAR PAN The balance returns to the Ready condition when the animal is removed from the pan ADJUSTMENTS The Animal Weigh level...

Page 20: ...ay 3 5 6 Totalize Cont 3 6 Additional Features 3 6 1 Weigh Below The Adventurer Pro balance is equipped with a weigh below hook NOTE Before turning the balance over install the cone cover to prevent d...

Page 21: ...rns on when the display becomes unstable or when a button is pressed The backlight turns off 5 seconds after the display becomes stable or after 5 seconds with no button presses The backlight is alway...

Page 22: ...or near the midpoint of the balance s weighing range and a weight at or near the balance s specified capacity Calibration Masses Before beginning calibration make sure masses are available Masses req...

Page 23: ...n Off End Setup Legal Trade When set On the balance operates in compliance with Weights and Measures regulations Auto Tare When set On the balance will automatically tare the first item placed on the...

Page 24: ...mode On or Off Count Allows setting the counting mode On or Off If Count is set On APW optimize can be set On or Off Percent Allows setting the percent weighing mode On or Off Check Weigh Allows sett...

Page 25: ...return to the first available unit PRINT 1 Output When Stable On Off GLP Tare On Off Auto PrintOff Cont Interval When Stable 1 3600 seconds Stable Load Load Zero Content Num Only Off all others On He...

Page 26: ...Odd 7 No Par 8 No Parity Handshake Off XONXOFF Hardware End RS1 RS232 2 contains an identical menu and is available when the optional COM2 port is installed Power This menu item allows setting the Pow...

Page 27: ...s per day Date Set the date type M D Y D M Y Y M D M Y D Y D M D Y M and the actual date End GLP Data Press the Yes button to advance to the GLP Print submenu Press the No button to return to User ID...

Page 28: ...factory settings End Reset Press the Yes button to advance to the Lockout menu Press the No button to return to Setup 3 7 11 Lockout Use this submenu to prevent unauthorized changes to menu settings...

Page 29: ...dden The LEGAL TRADE menu item is hidden The AUTO ZERO menu item setting is set to 0 5d and locked The OutPUt WHENSTABLE menu item setting is set to ON and locked The CONTINUOUS setting in the AUTO PR...

Page 30: ...f GLP SET User ID is ON PROJ ID 1234567890 If GLP SET Proj ID is ON Name If GLP SET Name is ON If a tare value is entered these three items are printed if selected in the definitiion string 0 0200kg G...

Page 31: ...r to the Error Code table and take appropriate action 4 MAINTENANCE 4 1 Calibration Periodically verify calibration by placing an accurate weight on the balance and if calibration is required refer to...

Page 32: ...500562 SF42 Printer SF42 Calibration Weights ASTM Class 2 50g 49054 12 100g 49015 12 200g 49025 12 400g 49045 12 1000g 49016 12 2000g 49026 12 4000g 49046 12 4 5 Service Information If the Troubleshoo...

Page 33: ...d 40 C Power AC adapter To national standard as per list in Section 4 6 Balance power input 6 14 5 VAC 50 60Hz 4VA or 7 20VDC 4W Batteries 4 x AA LR6 1 5 V not included typical 20 h with alkaline batt...

Page 34: ...enu C al Yes No Back Exi t 70 On Zero Off Print Unit Function Mode Tare Menu Cal Yes No Back Exit On Zero Of f Print Uni t Function M ode Tare M enu Cal Yes No Back Exi t 4 Adventurer Pro Text pages 1...

Page 35: ...Animal Weighing Parts Counting Percent Weighing Check Weighing Totalize Tare Range To Capacity by Subtraction Stabilization Time s 2 5 1 5 3 3 2 2 2 Power Requirements AC Adapter Included or 4 AA Batt...

Page 36: ...34 x 0 0001 20 594 x 0 001 ounce 1 79895 x 0 00005 7 4075 x 0 0005 14 4625 x 0 0005 28 5720 x 0 0005 74 075 x 0 005 ounce troy 1 63970 x 0 00005 6 7515 x 0 0005 13 1820 x 0 0005 26 0420 x 0 0005 67 51...

Page 37: ...001 79 434 x 0 001 ounce 144 625 x 0 005 285 720 x 0 005 ounce troy 131 820 x 0 005 260 420 x 0 005 pennyweight 2636 4 x 0 1 5208 4 x 0 1 pound 9 0390 x 0 0005 17 8575 x 0 0005 tael Hong Kong 109 540...

Page 38: ...ntinuous Print SP Print displayed stable weight SLP Auto Print stable non zero displayed weight SLZP Auto Print stable non zero weight and stable zero reading xP Interval Print x Print Interval 1 3600...

Page 39: ...8 RTS 9 Remote Print 1 2 3 4 5 6 COM 2 MINI DIN Connector TARE PRINT External PRINT and or TARE switches may be installed as shown in the diagram Momentary contact switches must be used To enable thi...

Page 40: ...ve or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other than Ohaus In lieu of a properly returned warranty registrati...

Page 41: ...EN 38 Adventurer Pro 4 Adventurer Pro Text pages 15 to 40 P65 4 10 2003 6 00 AM 38 All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 42: ...Adventurer Pro EN 39 4 Adventurer Pro Text pages 15 to 40 P65 4 10 2003 6 00 AM 39 All manuals and user guides at all guides com...

Page 43: ...ok NJ 07058 USA Tel 973 377 9000 Fax 973 593 0359 With offices worldwide www ohaus com Ohaus Corporation 2003 all rights reserved P N 12103954 Printed in China 12103954 4 Adventurer Pro Text pages 15...

Reviews: