OHAUS 5000 Operator'S Manual Download Page 1

Operator Manual

OHAUS Aviator 5000

Summary of Contents for 5000

Page 1: ...Operator Manual OHAUS Aviator 5000...

Page 2: ...2 12 10 OHAUS Operator Manual Aviator 5000 Order number 72246393...

Page 3: ...ng with PLUs 11 3 3 Using tare 13 3 4 Zeroing 14 3 5 By count operation 14 3 6 Accumulating 15 3 7 Change function 16 3 8 Fix unit price and or tare 17 3 9 Hold function 18 3 10 Weighing with 100 g 1...

Page 4: ...elling while maintain ing the highest accuracy 1 2 Device overview 1 2 1 Keyboard The keyboard is divided into four sections The advanced function keys depend on the region 1 2a 3 2b 2c 4 1 PLU preset...

Page 5: ...PLU NET Net value gross minus tare push button tare exists FIX Unit price and or tare is fixed X Scale is in by count mode 100 g 100 g pricing is activated 1 2 1 2 lb pricing is activated 1 4 1 4 lb p...

Page 6: ...tures on the underside 2 3 4 5 The following connections are located on the underside of the scale 1 Adjustable feet 2 Grips 3 Power supply connection 4 Power supply storage box 5 Calibration button O...

Page 7: ...calibrated have a label indicating this on the packaging Scales with a green M on the type plate are ready for operation Scales which are calibrated in two stages have a label indicating this on the...

Page 8: ...ocks and vibrations No excessive temperature fluctuations No direct sunlight No strong drafts Select a stable vibration free and preferably horizontal location for your scale 2 3 Setting up the scale...

Page 9: ...minal end to the positive pole red or and the black terminal end to the negative pole black or 6 Close the battery compartment 7 Put the weighing pan back on The battery life is affected by charging a...

Page 10: ...a short display test All segments and status messages briefly light up the software version is displayed The scale is ready when the weight display appears 2 7 Cleaning CAUTION Damage to the scale Tu...

Page 11: ...Creating a PLU 1 Enter the unit price price kg 2 Press and hold the PLU key until a long beep can be heard P appears in the weight display 3 Enter the PLU number between 1 and 9999 4 Wait until the s...

Page 12: ...perator setup Step 7 ON 1 Place the item on the scale 2 Enter the corresponding PLU number The PLU is called up automatically Unit price and price to pay are displayed 3 Remove the item from the scale...

Page 13: ...your containers you can enter the tare weight via keyboard So you do not have to tare the empty container Taring an empty container 1 Place the empty container on the scale 2 Press the Tare key The we...

Page 14: ...kg In such cases the scale must be reset to zero The maximum allowed deviation to be compensated by zeroing is 2 of the weighing range Press the Zero key The weight display is set to zero 3 5 By coun...

Page 15: ...on is ended Use the C key to leave by count operation 3 6 Accumulating This functionality is only legal in certain regions 1 Place the first item on the scale 2 Carry out pricing as described above 3...

Page 16: ...change is displayed 4 Press the C key to return to normal weighing mode Multiple items 1 Carry out accumulating as described above 2 When the total is displayed press the Change key The total price t...

Page 17: ...ample on the scale 3 Carry out pricing as described above 4 Press the FIX key When removing the item from the scale the unit price and tare are still displayed 5 Place the next sample on the scale The...

Page 18: ...key again until a long beep can be heard 3 10 Weighing with 100 g 1 2 lb 1 4 lb price unit For many products customers are used to a price per 100 g 1 2 lb 1 4 lb This function is only available if pe...

Page 19: ...on is only available if permitted by the national W M regulations 1 Carry out pricing as described above 2 Press the EUR key The price to pay is displayed in the second currency 3 Press the EUR key ag...

Page 20: ...urrent setting of the step is displayed Changing settings To toggle between the settings of a setup step use the Enter On Off key When moving to another setup step the selected setting is con firmed 4...

Page 21: ...in bold print No Setting Description 1 Reset ON Reset operator setup functions to factory settings OFF Do not reset operator setup functions 2 Beeper ON Beep when a key is pressed OFF No sound when a...

Page 22: ...ery charging function disabled To change charging function you are asked to enter a passwort 55555 10 Function keys 0 Function keys disabled 1 Function keys enabled 11 PLU ON Storing PLUs enabled OFF...

Page 23: ...splayed refer to the error message list Error message list Error Cause Remedy E11 RAM error Call service technician E16 ROM error Call service technician E18 EEPROM error Call service technician E34 P...

Page 24: ...Operating temperature 10 C to 40 C Storage temperature 25 C to 50 C Electrical data Power supply 12 V DC Power consumption 50 mA Plug in adapter In 230 V AC 50 Hz Out 12 V DC 800 mA Charging current...

Page 25: ...electrical and electronic equipment Should you have any questions please contact the corresponding authorities or the dealer from whom this device was purchased If this device is passed on for example...

Page 26: ...26 12 10 OHAUS Operator Manual Aviator 5000 Order number 72246393...

Page 27: ...27 12 10 OHAUS Operator Manual Aviator 5000 Order number 72246393...

Page 28: ...Subject to technical changes 12 2010 Ohaus Corporation Printed in Switzerland Order number 72246393 www ohaus com...