1. 

Place the 1 CHANNEL DMX SWITCH device on a fl at, stable surface. Connect the power supply 

using the Power Input (1). Make sure that the power cable supports the power of the/s machine/s 

of FX you want to control.

2.  Make sure that the power switch (7) is in OFF position.

3.  Connect the DMX cable to the DMX IN connector (4). You can use either of the 3-pin or 5-pin DMX 

IN connectors according to your needs.

4.  You can connect other machines and DMX devices using the DMX OUT connector (5).

5.  Connect the machines to which you want to control the “POWER OUT”(3). The 1 CHANNEL DMX 

SWITCH supports up to 20A resistive load, or 15A inductive load.

6.  Switch on (7) the device 1 CHANNEL DMX SWITCH.

7.  If the 1 CHANNEL DMX SWITCH PACK is receiving DMX signal, the led on “SIGNAL” (9) will light up.

8.  Assign the OPERATING DMX channel (13) using the buttons “UP” and “DOWN”. Make sure that 

the channel selected is free.

SAFETY CHANNEL

9.  The 1 CHANNEL DMX SWITCH is equipped with a safety channel (10) that protects the operating 

channel against any unintended activation. Assign the channel you want to use as the safety   

channel by using the “UP” and “DOWN” buttons on the safety channel. Make sure that the 

channel selected is free. The operating channel is subject to the permission of the safety channel.

10.  To unlock the safety channel, your DMX controller must send a value between 40% and 60% to 

the security channel. When the safety channel is unlocked, the “ARMED” (12) led will light on and 

the operating channel is ready to be activated.

11.  After activating the desired channel, you should enable again the safety mode by sending to the 

safety channel a value outside of the 40-60%. 

12.  The 1 CHANNEL DMX SWITCH also allows you to work without safety channel. To disable this 

safety channel, simply press the “ENABLE / DISABLE” button (11) to disable position. The screen 

of the safety channel will display “DIS” and the led “ARMED”(12) will be lit permanently. To re-

enable the security channel press again the button “ENABLE / DISABLE”.

1. 

Coloque el 1 CHANNEL DMX SWITCH en una superfi cie llana y estable. Conecte la alimentación 

de corriente mediante el conector powercon de entrada (1). Asegúrese de que el cable de 

alimentación admite la potencia de la/s máquina/s de FX que quiere controlar.

2.  Asegúrese de que el interruptor de encendido (7) está en posición OFF.

3.  Conecte el cable DMX a la toma de entrada DMX “DMX IN” (4). Para su comodidad dispone de una 

toma DMX de 3 pin y otra de 5 pin.

4.  Puede conectar otras máquinas y dispositivos DMX utilizando la toma de salida DMX “DMX OUT” 

(5).

5.  Conecte la/s máquina/s que desea controlar a la toma “POWER OUT”(3). El 1 CHANNEL DMX 

SWITCH soporta hasta 20A de carga resistiva o 15A de carga inductiva.

6.  Encienda el dispositivo 1 CHANNEL DMX SWITCH (7).

7.  Si el 1 CHANNEL DMX SWITCH PACK está recibiendo señal DMX se encenderá el led “SIGNAL”(9).

8.  Asigne el canal DMX operativo (13) mediante los botones “UP” y “DOWN”. Asegúrese de que el 

canal seleccionados esté libre.