Check the ambient temperature
The operating atmosphere temperature should be in the range of -10 to 40
◦
C. If used
at high temperatures, the frictional heat generated during clutching and braking cannot be
dissipated, and the coil and friction parts may be damaged. Also, please note that when used
at low temperatures, moisture will adhere due to condensation.
Be careful of rust.
Make sure that the clutch and brake are free of rust. Especially when used in areas with
high salt content such as beach areas, the installation environment may promote the
generation of rust. In this case, please consider implementing rust prevention measures.
2) Point Inspection
If you inspect this clutch / brake regularly, you will be able to demonstrate its performance for a
longer period of time. The inspection period varies depending on the specific usage conditions
of the customer, so please contact us.
Is there any foreign matter or water or oil on the friction surface or rotating parts?
The clutch and brake are for dry use, so make sure that oil, water or dust does not get
into the friction surface. If foreign matter gets into the friction surface or rotating parts,
the performance of the clutch / brake may deteriorate.