INTRODUCTION

1

2 of 12

The Offshore System’s NMEA2000® 3185, J1939 to NMEA2000® Adaptor is designed to convert 

Engine, Transmission and Generator messages on the J1939 network onto the NMEA2000® 

network.

This unit is designed to operate in a protected marine environment such as an engine room. It is 

very important that it is installed and set up correctly according to this manual. Please read and 

follow the installation and setup instructions carefully to achieve the best results.

1.1 Firmware Revision

The information in this manual corresponds to firmware revision 1.1.3

1.2 Product Features

The 3185, J1939 to NMEA2000® Adaptor has the following features:

     • 

Connection to J1939 network using a 3 pole Wago cage clamp connector

     • 

Green LED confirming valid J1939 message reception.

     • 

NMEA2000® micro C interface plug

     • 

User Settable a NMEA2000® Device Instance using rotary switch

     • 

 Blue LED confirming NMEA2000® transmission

     • 

NMEA2000® Interface optically isolated from J1939

     • 

Power drawn only from NMEA2000® interface

     • 

 Panel or DIN rail mounting option

NOTE:

FOR SAFETY REASONS THIS UNIT DOES NOT HAVE THE CAPABILITY OF TRANSMITTING ANY 

MESSAGES ONTO THE J1939 NETWORK.

Summary of Contents for 3185

Page 1: ...J1939 to NMEA2000 Adaptor Part Numbers 3185 USER MANUAL Revision 1 01...

Page 2: ......

Page 3: ...res 2 2 Installation 3 2 1 Unpacking the box 3 2 2 Mounting the unit 3 2 3 Connecting the NMEA2000 Cable 3 2 4 Connecting the J1939 cable to the WAGO socket 4 2 5 J1939 Connections 4 3 Configuration 5...

Page 4: ...lts 1 1 Firmware Revision The information in this manual corresponds to firmware revision 1 1 3 1 2 Product Features The 3185 J1939 to NMEA2000 Adaptor has the following features Connection to J1939 n...

Page 5: ...following drawing Or the unit can be Din Rails mounted by attaching the Din Rail mounts to the case using the supplied M3 CSK screws and then clipping the unit to the Din Rail 2 3 Connecting the NMEA2...

Page 6: ...driver in the slot above the wire connection Then simply insert the wire into it s connection slot and release the cage clamp by removing the small screw driver This will produce a secure gas tight co...

Page 7: ...Software Identification The following two items can be configured directly on the 3185 using the two small rotary switches There are no other menu setups to worry about 3 1 J1939 Source The J1939 Sou...

Page 8: ...ers PGN127493 Transmission Parameters PGN65030 Generator Average Basic AC Quantities Protocol PGN126464 Tx Rx PGN List PGN126996 Product Information PGN059392 ISO Acknowledge PGN059904 ISO Request PGN...

Page 9: ...Classification Protected Degree of Protection IP40 Operating Temperature 25 C to 50 C Storage Temperature 40 C to 70 C Relative Humidity 93 RH 40 per IEC60945 8 2 Vibration 2 13 2Hz 1mm 13 2 100Hz 7m...

Page 10: ...ONSEQUENTIAL DAMAGES DAMAGES FOR LOSS OF USE LOSS OF ANTICIPATED PROFITS OR SAVINGS OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE IN NO EVENT SHALL OFFSHORE SYSTEMS AGGREGATE LIABILITY...

Page 11: ...Drive New Milton Hampshire BH25 6RH United Kingdom Tel 44 0 1425 610022 Fax 44 0 1425 614794 Email mail osukl com Web www osukl com Copyright 2015 Offshore Systems UK Ltd All rights reserved Our poli...