IST/198-I

 

The instrument is delivered equipped with 5 vanes. If necessary, the vanes can be cut by reference to the inner diameter 
of the piping.   
 

PADDLE DIMENSION 

 

 
 
 
 

TABLE OF 
FLOWS 

Piping Ø   Min setting (m3/h) 

Max setting (m3/h) 

1”  

0.6 (1)  

1.9 (2) 

1 ¼”  

0.8 (1.3)  

2.8 (3) 

1 ½”  

1.1 (1.7)  

4.1 (4.4) 

2”  

2.2 (3.1)  

6.1 (6.6) 

2 ½”  

2.8 (4.1)  

7.3 (7.8) 

3”  

4.3 (6.2)  

11.4 (12) 

4”  

6.1 (8.4)  

17.3 (18.4) 

5”  

9.3 (12.9)  

25.2 (26.8) 

6”  

12.3 (16.8)  

30.7 (32.7) 

8”  

38.6 (46.6)  

90.8 (94.2) 

 
Data inside brackets shown in the table refers to closing values, whereas data outside brackets refers to opening 
values. 
The flow switches are factory-set to the minimum trip value. 
By turning the adjusting screw that is inside the housing clockwise the opening value increases. 
 