OFFICINE OROBICHE S.r.l.
2/3
24010 Ponteranica (Bergamo) ITALY - Via Serena, 10 - Tel. +39 035 4530211 - Fax +39 035 570546 - www.officineorobiche.it - e-mail: [email protected]
******************************************************************************************************************************************************************
NOV. 2020
Information subject to change without prior notice
IST/198-I
The instrument is delivered equipped with 5 vanes. If necessary, the vanes can be cut by reference to the inner diameter
of the piping.
PADDLE DIMENSION
TABLE OF
FLOWS
Piping Ø Min setting (m3/h)
Max setting (m3/h)
1”
0.6 (1)
1.9 (2)
1 ¼”
0.8 (1.3)
2.8 (3)
1 ½”
1.1 (1.7)
4.1 (4.4)
2”
2.2 (3.1)
6.1 (6.6)
2 ½”
2.8 (4.1)
7.3 (7.8)
3”
4.3 (6.2)
11.4 (12)
4”
6.1 (8.4)
17.3 (18.4)
5”
9.3 (12.9)
25.2 (26.8)
6”
12.3 (16.8)
30.7 (32.7)
8”
38.6 (46.6)
90.8 (94.2)
Data inside brackets shown in the table refers to closing values, whereas data outside brackets refers to opening
values.
The flow switches are factory-set to the minimum trip value.
By turning the adjusting screw that is inside the housing clockwise the opening value increases.
Flow switch PLJ
Flow switch PLJ EN