2. MODEL IDENTIFICATION 
 

IVF/

.

.

.

.

V

Seals

xx

Special

Version

VITON

N

65

80

Empty

Internal materials (if anyi)

NEOPRENE TEFLON

MOPLEN

T

ASB. FREE

A

15

20

25

32

Body mat.

Acc

304

316

40

50

6

A

I

J

PVC

MOPLEN

/

M

P

2

5

PVC

AISI 316

SBE

E

SSR SSL

SPO SPA SPD SPV SLE SCE

CV-TM SPO-TM

Model

Connection diameter

100 125 150 200

SPG SBB

 

3. OPERATING PRINCIPLE 

The operating principle is based on the fluid passing through the instrument and its display through a transparent 
porthole (e.g. made from glass), or is made with the returned indicator. 
This passage can be further displayed with paddles (fixed or moving)), chain and drips. 
In model SPO, the paddle indicates the flow rate on a graduated scale that is silk-screen printed on the porthole. 

 
4. INSTALLATION 

4.1 INSTALLING THE INSTRUMENT 

Before installation, check the line connections and the instrument connections for compatibility. 
As regards the SPO model, the unit shall be installed in a perfectly horizontal position and the piping shall be rectilinear for at 
least 5D (D= inner diameter of the piping) upstream and 3D downstream. Remove the piece of cardboard (if any) that blocks 
the paddle. 
In cases when the instrument shows an arrow that indicates the direction of the flow, please comply with that indication at the 
assembling stage. Moreover, if the passage fluid is at high temperature or very cold, the user shall adopt insulation/protections 
that are able to minimize all differences in temperature from room temperature. 
Burdening the unit with external loads is strictly prohibited and it is the user’s duty to protect it from whatever stress; all uses 
as a point of support is not allowed. 
To avoid all effects of galvanic corrosion, never use materials featuring a different electrochemical potential, the user shall take 
all actions that are aimed at preventing such condition for the unit. 
The system shall be equipped with the prescribed safety valve, to remedy over pressure values that exceed the maximum value. 
For installation on piping exposed to strong vibration, please contact the customer service department. 
 

4.2 INSTALLATION IN AREAS OF SPECIAL CONCERN 

In cases when the units are installed in Areas that feature the presence of potentially explosive atmospheres, the user shall 
stick to the 

additional safety instructions 

attached to the standard instructions. 