OFFICINE OROBICHE 4070 Series Instruction Manual Download Page 7

       

OFFICINE OROBICHE   S.p.A.              

7/8

 

 

24010 Ponteranica (Bergamo) ITALY - via Serena, 10 - Tel. 0039/035/4530211 - Fax 0039/035/570546 - www.officineorobiche.it-e-mail:[email protected]

 

**************************************************************************************************************************************************************** 

JULY 14 

Under reserve of modifications 

IST//130-I 

10. RECOMMENDED SPARE PARTS (*) 

 
When ordering spare parts, always indicate the instrument’s serial number. 
You can find it on the ratings plate on the case (see Fig. 12) and has 5 digits preceded by the letter “F” (e.g.: F45678). 

 
11. TROUBLE-SHOOTING 

Series 4070 level switches are not normally subject to malfunctions. 
If the level switch fails to trip, check the displacer and the micro-switch as explained at paragraph 7 MAINTENANCE. 

 
12. DISPOSAL 

Once  the  level  switches  have  reached  the end of their working life, they should be sent for disposal in accordance with 
prevailing regulations. 
During their disposal, pay special attention to the polymers, resins and rubber used in their construction (PVC, PTFE, PP, 
PVDF, neoprene, viton etc.). 
Metal  components  may  be  recycled  after removing the gaskets, special coverings as requested by the customer or other 
plastic materials. 
WARNING: 
If  mercury  bulb  micro-switches  (code  VD)  have  been  installed,  they  must  be disposed of in accordance with prevailing 
regulations concerning toxic substances; the other types of micro-switch are not subjected to these regulations. 
 

 
 
 
 
 
 
 

OFFICINE

DISCONNE

Summary of Contents for 4070 Series

Page 1: ...s in a vertical position The models have one or two tripping units each of which can be fitted with single SPDT or double exchange contacts DPDT for low high level controls and or alarms 2 MODEL IDENT...

Page 2: ...is the user s duty to protect it from strain do not use it as resting point To avoid effects of galvanic corrosion any use of materials featuring a different electrochemical potential is prohibited T...

Page 3: ...at indicated on the ratings plate NEVER adjust or replace any components without having first read the relevant instructions carefully If in doubt contact our Customer Services NEVER lubrificate instr...

Page 4: ...h unit in the sump 3 in exactly the same position as before e adjust the tripping position by manually moving the magnet 4 against the sump 3 tighten grub screw 5 until the micro switch trips and allo...

Page 5: ...fficineorobiche it JULY 14 Under reserve of modifications IST 130 I 9 DRAWINGS OF CASE WITH DIMENSIONS CODE LIQUID TEMPERATURE ELECTRICAL CONNECTIONS A 10 135 EP WP R3 11 80 1 2 NPT 1 2 NPT R1 136 250...

Page 6: ...eranica Bergamo ITALY via Serena 10 Tel 0039 035 4530211 Fax 0039 035 570546 www officineorobiche it e mail info officineorobiche it JULY 14 Under reserve of modifications IST 130 I WP CASE WATER PROO...

Page 7: ...ck the displacer and the micro switch as explained at paragraph 7 MAINTENANCE 12 DISPOSAL Once the level switches have reached the end of their working life they should be sent for disposal in accorda...

Page 8: ...e Orobiche under any circumstance The instrument may be used for a maximum period of 10 years from the date of delivery After said period the customer has two alternatives 1 Replace the instrument wit...

Reviews: