OFFICINE OROBICHE 4070 Series Instruction Manual Download Page 1

 

 

 

OFFICINE OROBICHE   S.p.A. 

1/8

 

INSTRUCTIONS MANUAL FOR LEVEL SWITCHES 

SERIES 4070 

24010 Ponteranica (Bergamo) ITALY - via Serena, 10 - Tel. 0039/035/4530211 - Fax 0039/035/570546 - www.officineorobiche.it-e-mail:[email protected]

 

**************************************************************************************************************************************************************** 

JULY 14 

Under reserve of modifications 

IST//130-I 

 
1. INSTRUMENT DESCRIPTION 

Series 4070 level switches have been designed for external lateral installation on pressure tanks in a vertical position.  
The models have one or two tripping units, each of which can be fitted with single (SPDT) or double exchange contacts 
(DPDT) for low/high level controls and/or alarms. 
 

2. MODEL IDENTIFICATION 

 

407

XX

WP

Ex-d

EP

M4

WATER 

PROOF

CASE

WATER-PROOF

M2

M3

CURRENT

continuos

J

304

I

CONTACT

DISPLACER MATERIAL

AISI 316

AISI 316L

2

2L

DPDT

2

CONTACT  TYPE

WATER-PROOF

M6

M14

golden  contacts

with inert gas

BASIC

A

D

HG BULB 

VD

SPDT

Ø

Ø

BODY MATERIAL

C.S.

316

MODEL

PN 40

TRIPPING UNIT

DOUBLE

4

ANSI 150

2

ANSI 300

6

SINGLE

SEALED

NO STANDARD VERSION

FINNING

Ø

R1

R4

R3

PNA

ALUMINIUM

PNEUMATIC

Summary of Contents for 4070 Series

Page 1: ...s in a vertical position The models have one or two tripping units each of which can be fitted with single SPDT or double exchange contacts DPDT for low high level controls and or alarms 2 MODEL IDENT...

Page 2: ...is the user s duty to protect it from strain do not use it as resting point To avoid effects of galvanic corrosion any use of materials featuring a different electrochemical potential is prohibited T...

Page 3: ...at indicated on the ratings plate NEVER adjust or replace any components without having first read the relevant instructions carefully If in doubt contact our Customer Services NEVER lubrificate instr...

Page 4: ...h unit in the sump 3 in exactly the same position as before e adjust the tripping position by manually moving the magnet 4 against the sump 3 tighten grub screw 5 until the micro switch trips and allo...

Page 5: ...fficineorobiche it JULY 14 Under reserve of modifications IST 130 I 9 DRAWINGS OF CASE WITH DIMENSIONS CODE LIQUID TEMPERATURE ELECTRICAL CONNECTIONS A 10 135 EP WP R3 11 80 1 2 NPT 1 2 NPT R1 136 250...

Page 6: ...eranica Bergamo ITALY via Serena 10 Tel 0039 035 4530211 Fax 0039 035 570546 www officineorobiche it e mail info officineorobiche it JULY 14 Under reserve of modifications IST 130 I WP CASE WATER PROO...

Page 7: ...ck the displacer and the micro switch as explained at paragraph 7 MAINTENANCE 12 DISPOSAL Once the level switches have reached the end of their working life they should be sent for disposal in accorda...

Page 8: ...e Orobiche under any circumstance The instrument may be used for a maximum period of 10 years from the date of delivery After said period the customer has two alternatives 1 Replace the instrument wit...

Reviews: