background image

Officine Gullo

2

CAUTION

1.  These safety directions apply to different kinds of appliances. Please identify correctly the specific appliance in 

your possession (check the tag showing the characteristics).

2.  Before using the appliance, read the instruction manual carefully, as it contains important safety information on 

the proper installation, use and maintenance of the appliance. Please keep the instruction manual for further 
reference. 

3.  The appliance’s electrical safety is guaranteed only if the electrical system is earthed in accordance with 

the relevant regulations. It is of the utmost importance to follow such regulations; when in doubt, please 
consult a qualified electrician to have the electrical system thoroughly checked. The manufacturer declines all 
responsibility for damage caused by a badly-earthed electrical system

4.  Before connecting the appliance, make sure that the appliance’s technical characteristics shown on the tag 

correspond to those of the electrical system and gas distribution network. 

5.  Make sure that the electrical system and sockets can handle the appliance’s maximum power consumption as 

shown on the tag. When in doubt, please consult a qualified electrician.

6.  The appliance should be connected to the electric supply line by means of an omnipolar switch with a minimum 

contact opening of 3 mm

7.  If the power socket is not compatible with the plug, replace the socket with a proper one and consult a qualified 

electrician to make sure that the cable size can handle the appliance’s maximum power consumption. The use 
of adapters, multiple power boards and extension cords is not recommended.

8.  When not in use, switch off the general power supply to the appliance and close the gas supply valve.
9.  Do not obstruct the appliance’s cooling or heat dissipation vents.
10.  In case of damage to the appliance’s power cord, it must be replaced exclusively by the manufacturer’s 

authorized service center.

11.  The appliance must be used only for the purposes for which it has been expressly designed (cooking).All other 

uses (such as the heating of a room) are considered inappropriate and therefore dangerous. The manufacturer 
declines all responsibility for damage resulting from improper use of the appliance.

12.  The use of any electric appliance implies the observance of some basic rules. More specifically.

• 

Do not touch the appliance with wet or damp hands or feet; 

• 

Do not use the appliance with bare feet;

• 

Avoid the use of extension cords and, if necessary, take all precautions;

• 

Do not pull the power cord to disconnect the plug from the power socket;

• 

Do not leave the appliance exposed to atmospheric agents (rain, sun, etc.);

• 

Do not allow children or untrained persons to use the appliance.

13.  Before cleaning the appliance or performing maintenance work, disconnect the appliance by pulling the plug 

out of the power socket or turning off the main switch.

14.  In case of failure or malfunction, turn the appliance off, close the gas supply valve and do not attempt to carry 

out any repairs, which must be done exclusively by an authorized service center. 

Request the use of original spare parts only. Failure to comply with the above recommendations may compromise 
the appliance’s safety.

3

Officine Gullo

TABLE OF CONTENTS

INSTALLATION MANUAL

DECLARATION OF COMPLIANCE ..........................................................................................8
GAS TECHNICAL DATA TABLE ...............................................................................................8
ELECTRIC TECHNICAL DATA TABLE .........................................................................................8
INSTALLATION .....................................................................................................................9
CHECKING FOR ADEQUATE VENTILATION .............................................................................9
PIPE FOR GAS CONNECTION ..............................................................................................10
ELECTRIC CONNECTION .....................................................................................................10
EQUIPOTENTIAL ..................................................................................................................10
CHECKING HEAT OUTPUT ...................................................................................................10
CHECKING PRIMARY AIR TO THE MAIN BURNERS AND PILOT NOZZLES ...................................11
BURNERS TECHNICAL DATA TABLE .........................................................................................11
RULES FOR CONVERTING AND INSTALLING OTHER TYPES OF GAS ..........................................11
SUBSTITUTING THE NOZZLE IN THE COUP DE FEU BURNER .....................................................11
CHECKING FUNCTIONING .................................................................................................12
MAINTENANCE ..................................................................................................................12
SPARE PARTS .......................................................................................................................12

USER MANUAL

INSTRUCTIONS FOR USE .....................................................................................................12
LIGHTING AND ADJUSTING THE COUP DE FEU ......................................................................12
CLEANING AND MAINTENANCE .........................................................................................13
WHAT TO DO IN THE EVENT OF A BREAKDOWN ..................................................................14
PROCEDURE TO FOLLOW IF THE APPLIANCE IS NOT GOING TO BE USED FOR SOME TIME ........14

MAINTENANCE (only for qualified personnel)

 ...........................................................................14

INSTRUCTIONS FOR DISCHARGING GAS EMISSIONS ............................................................14

Summary of Contents for TPS4GP

Page 1: ...INSTRUCTIONS FOR INSTALLATION AND USE TPS4GP TPS8GP GAS COUP DE FEU FOR RESIDENTIAL AND PROFESSIONAL USE...

Page 2: ...le the appliance s maximum power consumption The use of adapters multiple power boards and extension cords is not recommended 8 When not in use switch off the general power supply to the appliance and...

Page 3: ...PILOT NOZZLES 11 BURNERS TECHNICAL DATA TABLE 11 RULES FOR CONVERTING AND INSTALLING OTHER TYPES OF GAS 11 SUBSTITUTING THE NOZZLE IN THE COUP DE FEU BURNER 11 CHECKING FUNCTIONING 12 MAINTENANCE 12 S...

Page 4: ...Fig A 1 TPS4GP 70 cm 73 cm 67 cm 97 cm 90 cm 3 cm 4 cm 62 cm 40 cm 70 cm G 1 2 E 10 cm 40 cm 40 cm 20 cm E G 1 2 E LEGEND Electric connection Connessione lettrica G Gas connection Connessione Gas E El...

Page 5: ...5 Officine Gullo Fig A 2 TPS8GP E Electrical Connection G Gas Connection E Electrical Connection G Gas Connection...

Page 6: ...Officine Gullo 6 Fig B COUP DE FEU 1 Injector 2 Pilot...

Page 7: ...7 Officine Gullo TOP WIRING DIAGRAM 1 Electrical connection 2 Push button starting burner 3 4 Power station starting burner Fig C...

Page 8: ...n force particularly concerning room ventilation and discharging gas emissions N B The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect installati...

Page 9: ...ion of fire and panic Connection and installation of appliance ventilation and exhaust removal systems shall be done according to the Manufacturer s instructions and by qualified technicians and accor...

Page 10: ...nce see technical data table EQUIPOTENTIAL The appliance must be connected to an equipotential system The connection screw is positioned at the back of the appliance and is identified by the symbol At...

Page 11: ...Injector 1 100 mm Min output adjustment 1 100 mm Pilot Injector 1 100 mm Consumption 130A 100 20 kg h 0 552 130A 100 20 kg h 0 544 195 adjustable 35 m3 st h 0 740 TPS8G Burner max 12 kW min 7 kW Burne...

Page 12: ...emoved the front panel Open rings The cocks can be changed by removing the front panel to change the thermocouples and burners you have to remove the rungs and trays USER MANUAL INSTRUCTIONS FOR USE A...

Page 13: ...re until the desired effect is achieved The brass details should then be dried Do not use polish as this is suitable for maintaining the gloss but not the antique finish and could result in an effect...

Page 14: ...ble manually NATURAL DISCHARGE FORCED DISCHARGE 1 Extractor hood 1 Extractor hood 2 Interlocking Fig 1 Fig 2 WHAT TO DO IN THE EVENT OF A BREAKDOWN Turn off the gas tap and notify the after sales serv...

Page 15: ...below the values prescribed by item 4 3 by the UNI CIG norm 8723 The relesase of gas to the appliance must be possible only manually In the event of installation the end part of the discharge pipe of...

Page 16: ...Tel 39 055 656 0324 info officinegullo com Via Della Torricella 29 Antella Bagno a Ripoli 50012 Florence Italy OFFICINEGULLO COM en international V 1 2 9 20...

Reviews: