Officine Gullo FLS4G Instructions Manual Download Page 2

Officine Gullo

2

CAUTION

1.  These safety directions apply to different kinds of appliances. Please identify correctly the specific appliance in 

your possession (check the tag showing the characteristics).

2.  Before using the appliance, read the instruction manual carefully, as it contains important safety information on 

the proper installation, use and maintenance of the appliance. Please keep the instruction manual for further 
reference. 

3.  The appliance’s electrical safety is guaranteed only if the electrical system is earthed in accordance with 

the relevant regulations. It is of the utmost importance to follow such regulations; when in doubt, please 
consult a qualified electrician to have the electrical system thoroughly checked. The manufacturer declines all 
responsibility for damage caused by a badly-earthed electrical system

4.  Before connecting the appliance, make sure that the appliance’s technical characteristics shown on the tag 

correspond to those of the electrical system and gas distribution network. 

5.  Make sure that the electrical system and sockets can handle the appliance’s maximum power consumption as 

shown on the tag. When in doubt, please consult a qualified electrician.

6.  The appliance should be connected to the electric supply line by means of an omnipolar switch with a minimum 

contact opening of 3 mm

7.  If the power socket is not compatible with the plug, replace the socket with a proper one and consult a qualified 

electrician to make sure that the cable size can handle the appliance’s maximum power consumption. The use 
of adapters, multiple power boards and extension cords is not recommended.

8.  When not in use, switch off the general power supply to the appliance and close the gas supply valve.
9.  Do not obstruct the appliance’s cooling or heat dissipation vents.
10.  In case of damage to the appliance’s power cord, it must be replaced exclusively by the manufacturer’s 

authorized service center.

11.  The appliance must be used only for the purposes for which it has been expressly designed (cooking).All other 

uses (such as the heating of a room) are considered inappropriate and therefore dangerous. The manufacturer 
declines all responsibility for damage resulting from improper use of the appliance.

12.  The use of any electric appliance implies the observance of some basic rules. More specifically.

• 

Do not touch the appliance with wet or damp hands or feet; 

• 

Do not use the appliance with bare feet;

• 

Avoid the use of extension cords and, if necessary, take all precautions;

• 

Do not pull the power cord to disconnect the plug from the power socket;

• 

Do not leave the appliance exposed to atmospheric agents (rain, sun, etc.);

• 

Do not allow children or untrained persons to use the appliance.

13.  Before cleaning the appliance or performing maintenance work, disconnect the appliance by pulling the plug 

out of the power socket or turning off the main switch.

14.  In case of failure or malfunction, turn the appliance off, close the gas supply valve and do not attempt to carry 

out any repairs, which must be done exclusively by an authorized service center. 

Request the use of original spare parts only. Failure to comply with the above recommendations may compromise 
the appliance’s safety.

3

Officine Gullo

INDEX

INSTALLATION MANUAL

DECLARATION OF COMPLIANCE ..........................................................................................8
TECHNICAL DATA TABLE .......................................................................................................8
INSTALLING THE APPLIANCE .................................................................................................8
CHECKING FOR ADEQUATE VENTILATION .............................................................................9
PIPE FOR GAS CONNECTION ..............................................................................................9
CHECKING HEAT OUTPUT ...................................................................................................10
RULES FOR CONVERTING AND INSTALLING OTHER TYPES OF GAS ..........................................10
CHECKING PRIMARY AIR IN MAIN BURNERS ..........................................................................10
TABLE OF BURNERS TECHINCAL DATA....................................................................................11

SUBSTITUTING THE NOZZLE IN THE MAIN BURNER (fig.B)

 .......................................................11

SUBSTITUTING THE NOZZLE IN THE PILOT BURNER (fig.B)

 ........................................................11

CHECKING FUNCTIONING .................................................................................................11
MAINTENANCE ..................................................................................................................12
SPARE PARTS (Fig.B) ..............................................................................................................12

USER MANUAL

LIGHTING THE MAIN BURNER ..............................................................................................12
CLEANING AND MAINTENANCE .........................................................................................13
WHAT TO DO IN THE EVENT OF A BREAKDOWN ..................................................................13
OBSERVATIONS AND ADVICE ...............................................................................................14
PROCEDURE TO FOLLOW IF THE APPLIANCE IS NOT  GOING TO BE USED FOR SOME TIME .......14

MAINTENANCE (only for qualified personnel)

 ...........................................................................14

INSTRUCTIONS FOR DISCHARGING GAS EMISSIONS ............................................................14

Summary of Contents for FLS4G

Page 1: ...INSTRUCTIONS FOR INSTALLATION AND USE FLS4G FRS4G FLS6G FRS6G FLRS6G FLS8G FRS8G FLRS8G GAS FRYTOP FOR RESIDENTIAL AND PROFESSIONAL USE...

Page 2: ...le the appliance s maximum power consumption The use of adapters multiple power boards and extension cords is not recommended 8 When not in use switch off the general power supply to the appliance and...

Page 3: ...TABLE OF BURNERS TECHINCAL DATA 11 SUBSTITUTING THE NOZZLE IN THE MAIN BURNER fig B 11 SUBSTITUTING THE NOZZLE IN THE PILOT BURNER fig B 11 CHECKING FUNCTIONING 11 MAINTENANCE 12 SPARE PARTS Fig B 12...

Page 4: ...ine Gullo 4 Fig A 1 F S4G 70 cm 73 cm 67 cm 97 cm 90 cm 3 cm 4 cm 62 cm 40 cm 70 cm 40 cm 20 cm G 1 2 10 cm G 1 2 LEGEND Gas connection Connessione Gas G G Gas Connection ISO 7 1 R1 2GM INSTALLATION M...

Page 5: ...5 Officine Gullo 60 cm 70 cm 60 cm 20 cm G 1 2 10 cm 70 cm 73 cm 67 cm 97 cm 90 cm 3 cm 4 cm 62 cm G 1 2 LEGEND Gas connection Connessione Gas G Fig A 2 F S6G G Gas Connection ISO 7 1 R1 2GM...

Page 6: ...Officine Gullo 6 80 cm 70 cm 80 cm 20 cm G 1 2 10 cm 3 cm 70 cm 73 cm 67 cm 4 cm 97 cm 62 cm 98 cm 90 cm G 1 2 LEGEND Gas connection Connessione Gas G Fig A 3 F S8G G Gas Connection ISO 7 1 R1 2GM...

Page 7: ...7 Officine Gullo 1 Knob 2 Control Panel clamp 3 Piezoelectric device 4 Valve 5 Gas pipes 6 Thermocouple 7 Pilot 8 Lighting spark plug 9 Injector 10 Clamp 11 Drip pan Fig B...

Page 8: ...the items of our sales conditions TECHNICAL DATA TABLE MODEL Dimensions cm Nominal Power TOT kW Gas Connection ISO 7 1 F S4G 40x70x29h 7 R GM F S6G 60x70x29h 10 5 R GM F S8G 80x70x29h 14 R GM L Smooth...

Page 9: ...ritish Standards latest editions concerned The installation transformation and repair of appliances for professional kitchens as well as removal due to malfunction and the supply of gas may be made on...

Page 10: ...heck the pressure tightness Connection for liquid gas G30 G31 The connection pressure for liquid gas is 30 mbar with butane and 37 mbar with propane Check the plate read the pressure and verify that t...

Page 11: ...nical data The main burner does not require any regulation of the primary air SUBSTITUTING THE NOZZLE IN THE PILOT BURNER fig B The flame of the pilot burner has fixed air The only operation necessary...

Page 12: ...ary to leave the appliance on without being used for approximately an hour or until the smell disappears LIGHTING THE MAIN BURNER Lighting the pilot burner Push and turn the thermostat knob into posit...

Page 13: ...uitable for maintaining the gloss but not the antique finish and could result in an effect that is not compliant with our products Any spots that may appear over time on the burnished brass surfaces s...

Page 14: ...ble manually NATURAL DISCHARGE FORCED DISCHARGE 1 Extractor hood 1 Extractor hood 2 Interlocking Fig 1 Fig 2 OBSERVATIONS AND ADVICE With appliances which have two cooking areas F S8G it is possible t...

Page 15: ...below the values prescribed by item 4 3 by the UNI CIG norm 8723 The relesase of gas to the appliance must be possible only manually In the event of installation the end part of the discharge pipe of...

Page 16: ...Tel 39 055 656 0324 info officinegullo com Via Della Torricella 29 Antella Bagno a Ripoli 50012 Florence Italy OFFICINEGULLO COM en international V 1 7 11 20...