background image

11

Officine Gullo

INSTALLATION

When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing 
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessible. It is 

advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed 

near walls, dividing panels, kitchen furniture, decorative finishing, etc. , these should be in flameproof material; otherwise 
it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations 

done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or installation 
which does not comply with the norms.

Attention!

  In accordance with international rules, when connecting the appliance, an automatic device enabling the 

disconnection of all contacts from the mains, must be installed above it, this device must have a contacts opening of at 
least 3 mm.

TECHNICAL ELECTRICAL DATA TABLE 

MODELS

DIMENSIONS

 cm

POWER SUPPLY

Power max 

kW

Absorbition 

max A

Power supply 

cable (Silicon)

CVS4E

40 x 70 x 29h

400Vac3N 50/60 Hz

5

7,25

5 x 1 mm²

CVCS4E

40 x 70 x 90h

400Vac3N 50/60 Hz

7,8

11,3

5 x 1,5 mm²

CVS6E

60 x 70 x 29h

400Vac3N 50/60 Hz

7,5

10,87

5 x 1,5 mm²

CVCS6E

60 x 70 x 90h

400Vac3N 50/60 Hz

13,5

19,48

5 x 2,5 mm²

TRANSFORMATION

MODELS

DIMENSIONS

 cm

POWER SUPPLY

Power max 

kW

Absorbition 

max A

Power supply 

cable (Silicon)

CVS4E

40 x 70 x 29h

230Vac3N 50/60 Hz

5

21,74

3 x 2,5 mm²

ELECTRIC CONNECTION

The appliance is supplied without the connection cable.
To install the power supply cable, proceed as follows:
• 

Disconnect the power supply.

• 

Remove the bottom panel.

• 

Push the connection cable through the cable blocker, connect the conductor wires to the corresponding terminals in 

the junction box and fix them into place.

• 

Block the cable with the cable blocker, and reassemble the front panel. The earth wire must be longer than the others 
so that if the cable blocker should break, it will disconnect after the tension wires.

N.B.

 The connection cable must have an adequate section for the power of the appliance and be resistant to a temperature 

of at least 150°C (see technical data table).

Summary of Contents for CVS4E

Page 1: ...INSTRUCTIONS FOR INSTALLATION AND USE CVS4E CVS6E CVCS4E CVCS6E ELECTRIC PASTA COOKER FOR RESIDENTIAL AND PROFESSIONAL USE...

Page 2: ...le the appliance s maximum power consumption The use of adapters multiple power boards and extension cords is not recommended 8 When not in use switch off the general power supply to the appliance and...

Page 3: ...CTRICAL DATA TABLE 11 TRANSFORMATION 11 ELECTRIC CONNECTION 11 EQUIPOTENTIAL 12 USER MANUAL STARTING UP 12 INSTRUCTIONS FOR USE 12 TURNING ON 12 EMPTYING THE TUB CVCS E 13 EMPTYING THE TUB CVS4E CVS6E...

Page 4: ...UAL FIG A 1 CVS4E 3 cm 4 cm 97 cm 62 cm 70 cm 90 cm 73 cm 67 cm E 70 cm 40 cm 20 cm 40 cm 40 cm E Su richiesta scarico posteriore Drain on the wall on request E LEGEND Electric connection Connessione...

Page 5: ...Officine Gullo E Electrical connection F Water connection ISO 7 1 3 4 M S Water drainage ISO 7 1 1 M FIG A 2 CVCS4E E Electrical connection F Water connection ISO 7 1 3 4 M S Water drainage ISO 7 1 1...

Page 6: ...70 cm 20 cm 60 cm 40 cm E 3 cm 4 cm 97 cm 62 cm 70 cm 90 cm 73 cm 67 cm E Su richiesta scarico posteriore Drain on the wall on request E LEGEND Electric connection Connessione Elettrica FIG A 3 CVS6E...

Page 7: ...0 cm 20 cm 60 cm 40 cm E 3 cm 4 cm 97 cm 62 cm 70 cm 90 cm 73 cm 67 cm E Su richiesta scarico posteriore Drain on the wall on request E LEGEND Electric connection Connessione Elettrica E Electrical co...

Page 8: ...witching Klemmenblock Bornier de commutation Switching terminal block Tablero de bornes de conmutaci n 5 Resistenze Widerst nde R sistances Elements Resistencias 6 Sonda di livello Pegelsonde Sonde de...

Page 9: ...tation Switching terminal block Tablero de bornes de conmutaci n 4 Resistenze Widerst nde R sistances Elements Resistencias 5 Spia bianca Kontrolleuchte wei Lampe t moin blanche White pilot light Pilo...

Page 10: ...ERISTICS The system must be connected to a drinking water supply with the following characteristics Failure to do so automatically invalidates the guarantee Total hardness 0 5 to 5 F to prevent the bu...

Page 11: ...l contacts from the mains must be installed above it this device must have a contacts opening of at least 3 mm TECHNICAL ELECTRICAL DATA TABLE MODELS DIMENSIONS cm POWER SUPPLY Power max kW Absorbitio...

Page 12: ...care Check the connection of the appliance and start it up following the instructions INSTRUCTIONS FOR USE Use the appliance only under surveillance Never start up the appliance without water With pas...

Page 13: ...the safety device A upwards and move lever B to open the outlet tap Once emptied the tub close the outlet tap ANOMALIES If the probe does not detect the presence of water in the tank for more than 15...

Page 14: ...uld then be dried Do not use polish as this is suitable for maintaining the gloss but not the antique finish and could result in an effect that is not compliant with our products Any spots that may ap...

Page 15: ...the after sales service PROCEDURE TO FOLLOW IF THE APPLIANCE IS NOT GOING TO BE USED FOR SOME TIME Turn off the appliance disconnect the power supply and clean the appliance as specified above MAINTE...

Page 16: ...Tel 39 055 656 0324 info officinegullo com Via Della Torricella 29 Antella Bagno a Ripoli 50012 Florence Italy OFFICINEGULLO COM en international V 2 3 9 18...

Reviews: