Battery Voltage Parameters
These values apply to a 12V system at 25°C. For a 24V system the values
have to be doubled.
Battery Type
Sealed
Gel
Flooded
Overvoltage disconnect
16.0V
16.0V
16.0V
Max. charging voltage
15.0V
15.0V
15.0V
Restart after overvoltage
15.0V
15.0V
15.0V
Equalizing load voltage
14.6V
——
14.8V
Boost load voltage
14.4V
14.2V
14.6V
Float load voltage
13.8V
13.8V
13.8V
Boost-restart load voltage
13.2V
13.2V
13.2V
Under voltage restart
12.6V
12.6V
12.6V
Under voltage warning
Restart
Voltage
12.2V
12.2V
12.2V
Under voltage warning
12.0V
12.0V
12.0V
Undervoltage disconnect
11.1V
11.1V
11.1V
Discharge threshold votlage
10.6V
10.6V
10.6V
Equalizing period
120min
——
120min
Boost period
120min
120min
120min