QM- IT2705 

                          3/4 

    ITOE0242-en

 

 

6.

 

Check the software versions 

To check the software version of the boards: 

a)  Go to the 

Information

 menu on the control panel 

 

On OEtroCom-3 control panel: 

 

-

  Access the menus by pressing the key    

-

  Select 

Information

 

menu with the rotary button  

 

-

  Select 

CU-GH06

 board menu 

-

  Select and validate parameter 

Software Version 

to view the CU-GH06 version. 

-

  To go back press key   

-

  Select and validate 

SCB-10

 board menu with the rotary button 

 

-

  Select and validate parameter 

Software Version 

to view the SCB-10 board version. 

 

On OEtroCom-2 control panel : 

 

 

-

  Access the menus by pressing simultaneously the two keys on the right, 

-

  Select the Information Menu   and access the menu with key 

 

-

  Select the desired PCB using the keys 

+

 / 

-

  

-

  Confirm the selection with 

-

  Scroll through the parameters using the + key:  

the software version appears at the end of the list. 

-

  Return to the main menu by pressing the 

 key. 

b)  Or check the 

label

 on the electronic board 

 

CU-GH06 board:  

      

 

 

SCB-10 board (OEtroCom-3) :  

        

 

 

 

 

 

Version 2.1 at least 

SCB-10_E 

Version 1.04 at least 

Summary of Contents for GMR 6160

Page 1: ...roCom 3 or OEtroCom 2 control panel 2 Check the software versions of the circuit boards Check the following points Circuit boards SCB 10 OEtroCom 3 must be in version 1 04 or higher All SCB 10 circuit boards must be at the same version Burner management circuit boards CU GH06 must be in version 2 1 or higher All CU GH06 circuit boards must be at the same version 3 Remove the 2 jumpers from the CB ...

Page 2: ...arameter NP006 Cascade Type Select the cascade type traditional or parallel Management of the cascade of boilers by successive addition or in parallel simultaneous operation 0 Traditional factory set Successive addition of additional boilers 1 Parallel All boilers start up at the same time NP007 CascTOutsideHeatParl Outdoor temperature that starts all cascaded appliances at the same time Factory s...

Page 3: ...0 board menu with the rotary button Select and validate parameter Software Version to view the SCB 10 board version On OEtroCom 2 control panel Access the menus by pressing simultaneously the two keys on the right Select the Information Menu and access the menu with key Select the desired PCB using the keys Confirm the selection with Scroll through the parameters using the key the software version...

Page 4: ...igher and All CU GH06 boards must be at the same version at least 2 1 or higher Appliance concerned Description Reference in spare parts GMR 6160 OEtroCom 3 or GMR 6160 OEtroCom 2 7718238 CU GH06 version 2 1 GMR 6160 OEtroCom 3 7774497 SCB 10_E version 1 04 GMR 6160 OEtroCom 3 7718239 Set of boards SCB 10 SW1 04 CU GH06 SW2 1 ...

Reviews: