background image

4

Operating Instructions and Parts Manual 

23976/23977

12/18

2018 OEMTOOLS

3 SPEED EVAPORATIVE COOLER

5.  Prior to putting your cooler away for winter, always:

 

a.  Drain the tank and wipe it clean.

 

b.  Clean the filter.

 

c.   Re-assemble and run on FAN ONLY for  

30 minutes to dry out the filter.

6.  Having completed assembly of your cooler, position the 

unit with its back to an open window or door. This will allow 

fresh air to be drawn through the cooler and exhausted 

from the room. Constant air change is essential and part of 

the fresh air benefit from evaporative air cooling.

7. 

Remember: your cooler has been designed to operate 

even if it runs out of water. No damage will be caused 

to the pump if cooler runs out of water.

FILLING COOLER OR CONNECTING TO  

WATER SUPPLY

Move the cooler to an area where it can be filled.

MANUAL FILL

The cooler can be filled via the front fill door by hose or 

bucket. Using the water fill window to monitor water level, 

simply depress the fill door and the spring lock will release 

and open it. To close, simply push it closed and locked.

AUTO FILL CONNECTIONS

Connect to a water supply using a garden hose or coil hose 

(supplied by customer), or a direct water line. (Parts for 

direct connection can be obtained at any hardware store.) 

Simply attach hose adapter (supplied with cooler) to the 

float valve nipple protruding from cooler. Verify water tight 

connections by visually examining the hose connection.

CAUTION:

Water inlet pressure should be limited to a maximum 50 PSI. 

If valve is overcome, install a pressure reducer (25 PSI) on 

nipple first. (It can be obtained at hardware stores in the 

Irrigation section.) Hose bib needs only be cracked open 

slightly to supply water to float valve, and the cooler only 

needs to be about half filled when in auto fill configuration. 

The float is already set to that level. 

USING THE ROTARY MECHANICAL CONTROL 

SWITCHES (CLOCKWISE FROM OFF):
Rotary Switch #1: Controls pump function
Rotary Switch #2: Controls fan functions

• Off              
• L: Low Fan
• M: Medium Fan
• H: High Fan

Rotary Switch #3: Controls swing function

ON/OFF SWITCHES

Each function is controlled independently.  To dry the 

pads or use the cooler as a fan only, simply turn the fan 

switch on to desired speed while leaving the pump power 

switch in the “OFF” position.

ADDITIONAL FEATURES

• GFCI plug end

MAINTENANCE

WARNING

DO NOT remove the back panel with the 

cooler running.

NOTE

:

 

For best operation and long useful life, the 

following maintenance and cleaning procedures should 

be followed.

CLEANING COOLER AND PADS

At regular intervals, the cooler should be shut down and 

disconnected from power supply. The water tank should 

be drained of dirty water and sprayed out with fresh 

water and refilled. The more you do this, the better it will 

work and less calcium will develop on pads and/or other 

surfaces. You may spray through the cooling pads to 

wash them out and allow water to deposit in the tank to 

be drained away. The removable panel and media pad 

can be sprayed out on the ground to clean pad. Use light 

pressure when spraying pads. NEVER spray pads with 

water while cooler is operating and fan is running. This 

can cause damage to motor and will void the warranty. 

Summary of Contents for 23976

Page 1: ...the equipment understands and follows these safety instructions as well Operating Instructions and Parts Manual 23976 23977 FOR CUSTOMER SERVICE Technical Question CALL 1 866 458 2472 customerservice...

Page 2: ...olers DO NOT USE until repaired 13 Use only accessories that are recommended by the manufacturer for your model Accessories that may be suitable for one tool may become hazardous when used on another...

Page 3: ...erse the evaporative cooler in water 14 Confirm the rear panel is attached before operating 15 This evaporative cooler is not intended for use by people including children with reduced physical sensor...

Page 4: ...mum 50 PSI If valve is overcome install a pressure reducer 25 PSI on nipple first It can be obtained at hardware stores in the Irrigation section Hose bib needs only be cracked open slightly to supply...

Page 5: ...re this procedure The submersible pump is mounted inside the tank to the bottom with a retention bracket While you are cleaning the cooler the pump may be removed and the strainer cap on the bottom of...

Page 6: ...or 6037051 6061051 3 Rigid Media Set CP370 CP610 4 Control Board 6037069 6037069 5 Casters 6036061 6060061 6 Casters w lock 6036062 6060062 7 Fan Blade 6037052 6061052 8 Float Valve 6018058 6018058 9...

Page 7: ...slow at start up 3b 1 Replace motor capacitor 4 Louver does not operate 4 1 Louver does not move Move swing switch position to ON 4 2 Check Oscillator motor for proper placement and operation 5 Water...

Page 8: ...ce blades bits files and batteries as necessary OEMTOOLS reserves the right to makes any changes in construction or design at any time without any obligation in incorporating such changes to tools or...

Reviews: