background image

Technical specifications 

 
Minimum operating voltage 

7 volts 

Maximum operating voltage 

18 volts 

 

(operating at or near maximum rating for an extended time can damage unit) 

Gauge Range 

 

 

0.0 - 17.0 volts 

Gauge 

Resolution 

  - 0.1 

Gauge 

accuracy 

  - 

±

0.1 V 

Typical current draw (@ 13.8V)  - 

0.13 A 

Warning indicator max current 

0.3 A 

 
 
 

ODYSSEY SERIES DIGITAL GAUGE LIMITED WARRANTY 

 

DAKOTA DIGITAL (the Company) warrants to the ORIGINAL PURCHASER of this product that should it, under 

normal use and condition, be proven defective in material or workmanship within 24 MONTHS FROM THE DATE OF 
PURCHASE, such defect(s) will be repaired or replaced (at the Company’s option) without charge for parts or labor 
directly related to repairs of the defect(s). 

To obtain repair or replacement within the terms of this Warranty, the product is to be delivered with proof of 

warranty coverage (e.g. dated bill of sale), name, address, phone number, and specification of defects, transportation 
prepaid, to the factory.  This Warranty is valid for the original purchaser only and may not be transferred. 

This warranty does not cover nor extend to damage to vehicle  electrical system.  This Warranty does not apply 

to any product or part thereof which in the opinion of the Company has been damaged through alteration, improper 
installation, mishandling, misuse, neglect, or accident. 

This Warranty is in lieu of all other express warranties or liabilities.  ANY IMPLIED WARRANTIES, INCLUDING 

ANY IMPLIED WARRANTY OF MERCHANTABLITY, SHALL BE LIMITED TO THE DURATION OF THIS WRITTEN 
WARRANTY.  ANY ACTION FOR BREACH OF ANY WARRANTY HEREUNDER INCLUDING ANY IMPLIED 
WARRANTY OF MERCHANTABLITY MUST BE BROUGHT WITHIN A PERIOD OF 24 MONTHS FROM DATE OF 
ORIGINAL PURCHASE.  IN NO CASE SHALL THE COMPANY BE LIABLE FOR ANY CONSEQUENTIAL OR 
INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESSED OR IMPLIED, 
WHATSOEVER.  No person or representative is authorized to assume for the Company any liability other that expressed 
herein in connection with the sale of this product. 

The Company does not warrant that this product cannot be compromised or circumvented.  THE EXTENT OF 

THE COMPANY’S LIABILITY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT PROVIDED 
ABOVE AND, IN NO EVENT, SHALL THE COMPANY’S LIABILITY EXCEED THE PURCHASE PRICE PAID TO THE 
PURCHASER FOR THE PRODUCT. 

 

Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation if 

incidental or consequential damage so the above limitations or exclusions may not apply to you.  This warranty gives you 
specific legal rights and you may also have other rights which vary from state to state. 

 
 
 
 

 
 
 

  

     4510 W. 61ST St. N.,  Sioux Falls, SD  57107 
   Phone: (605) 332-6513      FAX: (605) 339-4106  

 

         

www.dakotadigital.com

[email protected]

 
 

 ©Copyright 1997 Dakota Digital Inc. 

Summary of Contents for ODY-05-2

Page 1: ...curate readings quickly after being powered up Night dimming with lens label lighting High Visibility VFD display for sunlight readability The voltage gauge for remote monitoring will read the voltage at an extra battery amplifier power connection or other system that needs to be monitored The gauge will be powered from a standard accessory terminal and not from the point it is monitoring The volt...

Page 2: ...Make sure the key is off so the gauge is not powered 2 Press and hold the SET button This is located behind the hole located on the back side of the gauge as shown in figure 1 3 Turn the key on while the SET button is being held 4 Release the button The gauge should show LO and then switch to a reading between 8 0 and 11 0 5 Turn the warning adjustment pot until the desired low voltage limit is sh...

Page 3: ...s or lights a relay will need to be used to switch the indicator on Dakota Digital s RLY 1 30A relay may be used for this One of the coil wires should be connected to 12 volts and the other coil wire connected to the yellow warning wire When the gauge is outside its limits the relay will turn on The relay contact wires can be used to switch the higher current WARNING CONNECTING A HIGH CURRENT INDI...

Page 4: ... 9 16 x 1 11 16 It should be inserted into the opening from the front and the U clamp will be installed from the back Tighten the two nuts on the U clamp so that the gauge is secure Figure 2 shows the required cut out for the gauge Figure 3 shows how the gauge mounts ...

Page 5: ...air or replace indicator Gauge output has been Return gauge for repair see instructions damaged Gauge will not dim Blue wire is not connected Check wiring connections correctly Gauge remains dim at all Blue wire is getting power Connect blue wire to location that only times all of the time has power when the headlights are on Battery is very low Recharge or replace vehicle battery Gauge is damaged...

Page 6: ...e neglect or accident This Warranty is in lieu of all other express warranties or liabilities ANY IMPLIED WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABLITY SHALL BE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY ANY ACTION FOR BREACH OF ANY WARRANTY HEREUNDER INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABLITY MUST BE BROUGHT WITHIN A PERIOD OF 24 MONTHS FROM DATE OF ORIGINAL PURCHASE IN ...