Odyssey Extreme Series Technical Manual Download Page 4

Publication No: US-ODY-TM-AA  September 2016

www.odysseybattery.com

EXTENDED DISCHARGE CHARACTERISTICS 

In addition to its excellent pulse discharge capabilities, the ODYSSEY

®

 battery can deliver many deep discharge cycles, 

yet another area where the ODYSSEY battery outperforms a conventional SLI battery, which can deliver only a few deep 
discharge cycles. 

The following twenty graphs show detailed discharge characteristics of the entire ODYSSEY battery line. The end of discharge 
voltage in each case is 10.02V per battery or 1.67 volts per cell (VPC). Each graph shows both constant current (CC) and 
constant power (CP) discharge curves at 77ºF (25ºC). The table next to each graph shows the corresponding energy and 
power densities. The battery run times extend from 2 minutes to 20 hours. 

ODYSSEY

®

 Extreme Series

™ 

Batteries 

PC310 performance data at 77°F, per 12V module 

Time 

Watts 

Amps  Capacity  Energy 

ENERGY AND POWER DENSITIES 

(W) 

(A) 

(Ah) 

(Wh) 

W/liter  Wh/liter  W/kg 

Wh/kg 

2 min 

738 

80.8 

2.7 

24.6 

613.2 

20.4 

273.3 

9.1 

5 min 

473 

43.2 

3.6 

39.4 

393.3 

32.8 

175.3 

14.6 

10 min 

312 

26.0 

4.4 

53.1 

259.4 

44.1 

115.6 

19.7 

15 min 

236 

19.0 

4.8 

59.0 

196.0 

49.0 

87.4 

21.8 

20 min 

191 

15.0 

5.0 

62.9 

158.4 

52.3 

70.6 

23.3 

30 min 

139 

10.8 

5.4 

69.3 

115.1 

57.6 

51.3 

25.7 

45 min 

98 

7.6 

5.7 

73.9 

81.8 

61.4 

36.5 

27.4 

1 hr 

76 

6.0 

6.0 

76.4 

63.5 

63.5 

28.3 

28.3 

2 hr 

41 

3.2 

6.5 

81.0 

33.7 

67.3 

15.0 

30.0 

3 hr 

28 

2.3 

6.8 

82.8 

22.9 

68.8 

10.2 

30.7 

4 hr 

21 

1.8 

7.0 

83.7 

17.4 

69.6 

7.8 

31.0 

5 hr 

17 

1.4 

7.2 

84.5 

14.0 

70.2 

6.3 

31.3 

hr 

11  0.9  7.6 86.1 8.9 71.5 4.0 31.9 

10 

hr 

9  0.8  7.8 86.8 7.2 72.1 3.2 32.2 

20 

hr 

5  0.4  8.6 90.5 3.8 75.2 1.7 33.5 

PC370 performance data at 77°F, per 12V module 

ENERGY AND POWER DENSITIES

Time 

Watts 

Amps  Capacity  Energy 

(W) 

(A) 

(Ah) 

(Wh) 

W/litre  Wh/litre 

W/kg 

Wh/kg 

2 min 

1320 

127.1 

4.2 

44.0 

612.2 

20.4 

231.6 

7.7 

5 min 

768 

70.7 

5.9 

64.0 

356.2 

29.7 

134.7 

11.2 

10 min 

485 

43.6 

7.3 

80.9 

225.1 

37.5 

85.2 

14.2 

15 min 

365 

32.4 

8.1 

91.4 

169.5 

42.4 

64.1 

16.0 

20 min 

297 

26.1 

8.7 

99.0 

137.8 

45.9 

52.1 

17.4 

30 min 

220 

19.1 

9.6 

109.8 

101.9 

50.9 

38.5 

19.3 

45 min 

161 

13.8 

10.4 

120.6 

74.6 

55.9 

28.2 

21.2 

1 hr 

128 

10.9 

10.9 

127.8 

59.3 

59.3 

22.4 

22.4 

2 hr 

73 

6.1 

12.2 

145.2 

33.7 

67.3 

12.7 

25.5 

3 hr 

51 

4.3 

12.9 

153.7 

23.8 

71.3 

9.0 

27.0 

4 hr 

40 

3.3 

13.3 

159.6 

18.5 

74.0 

7.0 

28.0 

5 hr 

33 

2.7 

13.7 

163.8 

15.2 

76.0 

5.7 

28.7 

8 hr 

21 

1.8 

14.4 

171.8 

10.0 

79.7 

3.8 

30.1 

10 hr 

18 

1.5 

14.5 

175.2 

8.1 

81.3 

3.1 

30.7 

20 hr 

0.8 

15.2 

183.6 

4.3 

85.2 

1.6 

32.2 

Summary of Contents for Extreme Series

Page 1: ...Technical Manual NINTH EDITION Publication No US ODY TM AA September 2016...

Page 2: ...TPPL construction that has made ODYSSEY batteries the choice of automotive technicians and consumers nationwide Introduction 3 Why use ODYSSEY batteries 3 Extended discharge characteristics 4 Performa...

Page 3: ...of charge At lower temperatures storage times will be even longer Deep discharge recovery The ease with which an ODYSSEY battery can recover from a deep discharge is extraordinary A later section on...

Page 4: ...19 0 4 8 59 0 196 0 49 0 87 4 21 8 20 min 191 15 0 5 0 62 9 158 4 52 3 70 6 23 3 30 min 139 10 8 5 4 69 3 115 1 57 6 51 3 25 7 45 min 98 7 6 5 7 73 9 81 8 61 4 36 5 27 4 1 hr 76 6 0 6 0 76 4 63 5 63...

Page 5: ...9 61 4 15 3 20 min 259 22 5 7 5 86 2 129 3 43 1 49 7 16 6 30 min 190 16 3 8 2 95 0 95 0 47 5 36 5 18 3 45 min 138 11 8 8 8 103 4 68 9 51 7 26 5 19 9 1 hr 111 9 5 9 5 111 3 55 7 55 7 21 4 21 4 2 hr 62...

Page 6: ...15 min 686 59 8 15 0 171 6 153 5 38 4 58 2 14 5 20 min 554 48 0 16 0 184 8 124 0 41 3 47 0 15 7 30 min 405 34 8 17 4 202 3 90 5 45 3 34 3 17 1 45 min 291 24 9 18 7 218 5 65 2 48 9 24 7 18 5 1 hr 234 2...

Page 7: ...28 72 3 24 1 276 0 126 8 42 3 47 6 15 9 30 min 610 53 3 26 6 304 8 93 4 46 7 35 0 17 5 45 min 443 38 8 29 1 332 6 67 9 50 9 25 5 19 1 1 hr 359 31 5 31 5 359 0 55 0 55 0 20 6 20 6 2 hr 201 17 7 35 4 40...

Page 8: ...8 15 min 2037 182 0 45 5 509 3 163 0 40 7 74 3 18 6 20 min 1692 149 8 49 9 564 0 135 4 45 1 61 7 20 6 30 min 1282 112 1 56 0 641 0 102 6 51 3 46 8 23 4 45 min 955 82 5 61 9 716 2 76 4 57 3 34 9 26 1...

Page 9: ...51 0 37 7 429 9 156 2 39 0 62 3 15 6 20 min 1401 122 0 407 467 1 127 3 42 4 508 16 9 30 min 1034 89 1 44 5 516 8 93 9 46 9 37 4 18 7 45 min 750 64 1 48 1 562 6 68 1 51 1 27 2 20 4 1 hr 605 51 4 51 4 6...

Page 10: ...9 36 6 88 4 14 7 15 min 2393 212 4 53 1 598 3 168 6 42 2 67 8 16 9 20 min 1957 212 4 53 1 598 3 168 6 42 2 67 8 16 9 30 min 1451 126 1 63 0 725 3 102 2 51 1 41 1 20 5 45 min 1057 90 9 68 2 793 0 74 5...

Page 11: ...1971 175 7 29 3 328 6 209 7 35 0 93 4 15 6 15 min 1501 131 9 33 0 375 2 159 6 39 9 71 1 17 8 20 min 1222 106 6 35 5 407 5 130 0 43 3 57 9 19 3 30 min 903 77 8 38 9 451 3 96 0 48 0 42 8 21 4 45 min 657...

Page 12: ...6 28 0 8 hr 74 6 2 49 4 592 9 8 6 69 1 3 8 30 1 10 hr 61 5 1 50 6 607 4 7 1 70 8 3 1 30 8 20 hr 33 2 8 55 1 657 0 3 8 76 6 1 7 33 3 65 760 performance data at 77 F per 12V module Time Watts Amps Capa...

Page 13: ...g life battery option in foat applications At room temperature 77 F or 25 C these batteries have a design life of 10 years in foat applications at end of life an ODYSSEY battery will still deliver 80...

Page 14: ...rged over 20 hours 0 05C10 rate 2 to 10 20V After the discharge2 a 5 resistor was placed across the battery terminals and the battery kept in storage for 28 days At the end of the storage period the b...

Page 15: ...eries To properly charge your premium ODYSSEY battery EnerSys has developed a special charge algorithm It is designed to rapidly and safely charge these batteries Called the IUU profle a constant curr...

Page 16: ...Samples 1 2 Given a 24hr CC charge 650mA prior to cycle 55 then resumed cycling Sample 3 Given a 24 hr CC charge 650mA at cycle 359 then resumed cycling Sample 4 Given a 24 hr CC charge 650mA at cycl...

Page 17: ...PC1500 PC1700 11 hours 5 5 hours 65 760 48 720 11 hours 5 5 hours PC1220 and 65 PC1750 PC1800 FT Not 17 hours Recommended 31 800 31M 800 16 hours 8 hours PC1350 31 PC2150 and 31M PC2150 PC2250 20 hou...

Page 18: ...and record the time taken to reach this voltage Let the battery rest for an hour and repeat Steps 1 through 4 If the time taken by the battery to drop to 10 00V is longer in the second discharge than...

Page 19: ...tive lead from one end of the pack the frst or last battery and the negative lead from the other end of the pack The two methods are illustrated above Solid lines and arrows indicate positive terminal...

Page 20: ...ond discharge is unrealistic The PHCA a short duration about three to fve seconds high rate discharge is more realistic Because the discharge is for such a short time it is more like a pulse Are these...

Page 21: ...uct mishandling What is so special about thin plate pure lead technology Is it a new technology The answer lies in the very high purity 99 99 of our raw lead materials making our product very special...

Page 22: ......

Reviews: