M-UM009-01 Page 4

Notes On Testing

AC 030 Battery Bypass

Blue connectors (UPC) have a straight ferrule with a domed interface. Green connectors 

(APC) have an eight-degree angled ferrule with a domed interface.

UPC and APC connectors are not compatible. NEVER connect UPC and APC connectors 

together, OR plug an APC connector into the DLS 360 unit. This can cause irreparable 

damage to both connectors.

ODM offers the AC 030 wall plug for users who wish to leave their DLS 360 turned on for 

long periods of time. This is NOT a charger, but rather powers the unit from a wall outlet.

Light Source Accessories

Light Source Adapters

Part Number

Description

AC 022B

SC Adapter

AC 023B

FC Adapter

AC 024B

ST Adapter

AC 025B

LC Adapter

Patch Cord Accessories

Part Number

Description

AC 500

SM SC-LC - 1m simplex

AC 505

SM SC-ASC - 1m simplex

AC 501

SM SC-SC - 1m simplex

AC 502

SM LC-LC - 1m simplex

AC 600

SC-SC simplex bulkhead

AC 601

LC-LC simplex bulkhead

AC 602

LC-LC duplex bulkhead

Phone: 603-524-8350
Email: 

[email protected]

Web: 

www.odm-inc.com

Contact ODM Support

Summary of Contents for DLS 360

Page 1: ...ngth is selected The red light will blink to indicate when the 2kHz modulation is turned ON 3 Low Battery Indicator A red indicator light will appear when the CR2 battery power is low Replace the battery to return to normal operation of the DLS 360 4 Power Button Press this button to turn the DLS 360 ON and OFF The unit will turn off automatically after 15 minutes To bypass the auto shutoff hold t...

Page 2: ...t The DLS 360 transmits either the 1490nm or 1625nm wavelength on singlemode fiber Be sure to use a test jumper to mate the DLS 360 to the fiber under test Test Jumper Mate Connectors Appropriately Signal Propagates Down Fiber Caution Invisible Laser Radiation Please note that 1490nm and 1625nm wavelengths are not visible to the human eye Do not look directly into the output port of the DLS 360 or...

Page 3: ...velength indicator will blink The 2kHz modulation will be recognized by optical power meters further down the fiber and indicated by a 2kHz notification onscreen and a loud beep The modulated tone may also be recognized through the fiber jacket when a Live Fiber Identifier is used The LFI introduces a bend into the fiber which leaks light from the core onto the detector of the power meter When usi...

Page 4: ...sers who wish to leave their DLS 360 turned on for long periods of time This is NOT a charger but rather powers the unit from a wall outlet Light Source Accessories Light Source Adapters Part Number Description AC 022B SC Adapter AC 023B FC Adapter AC 024B ST Adapter AC 025B LC Adapter Patch Cord Accessories Part Number Description AC 500 SM SC LC 1m simplex AC 505 SM SC ASC 1m simplex AC 501 SM S...

Reviews: