4-14 Peripheral Equipment
101–1386–001
Edition 2
10. Verify that the server is operational and that the CPU channels are active, as follows:
a. Log onto the server using the system manager password.
b. From the Main Menu, type 6 and press Return to access Menu 6 – Dialing and
Serial Channel Parameters.
c. Type 3 and press Return to access menu 6.3, Define CPU Serial Channel.
d. On the screen, the Active Type and Stored Type columns should display SMT for
the channel configured.
-
If the column displays SMT for the channel configured, the channel has been
configured correctly and is operational.
-
If the Active Type column is blank for the channel configured, but the Stored
Type column displays SMT, the reboot process was not successful. Reboot
the server and confirm that it is operational, as described in steps 9 and 10.
After you configure the CPU serial channel, if you are connecting a modem to a
remote terminal, proceed to the next section. If you are connecting a modem to a PC,
skip to the “Connecting the PC Modem to a PC” section, page 4-17.
Connecting the SMT Modem to a Remote
Terminal
Use the following procedure to connect the Boca 14.4Kbps V.32bis modem to the
terminal:
1. Turn on the SMT remote terminal. Following the manufacturer’s instructions, set up
the terminal to communicate with the modem. Set the terminal to 9600 baud, 8 data
bits, 1 stop bit, no parity, and XON/XOFF protocol for both transmit and receive (if
applicable).
2. Connect one end of the straight, 25-pin, male-to-male cable to the SMT modem or
datacomm connector on the back of the terminal. Refer to the documentation that
came with your modem for the location of the connector.
3. Connect the other end of the 25-pin, male-to-male cable to the DB25 connector on
the back of the SMT modem.
4. Connect the modular telephone cord to the RJ11 jack for the telephone line.
5. Connect the other end of the modular telephone cord to the jack labeled LINE on the
back of the SMT modem. Do not connect the line cord to the jack labeled PHONE.
Refer to the documentation that came with your modem for the location of the
connector.