4-34
Installation and Maintenance Volume
Octel Overture 200/300 Serenade 3.0
PB60014–01
External Alarm Port
The external alarm port uses a 9-pin DB9 female connector with the following pin arrangement:
Use connector J3 for the Octel Overture 200.
Use connector J5 for the Octel Overture 300.
The external-alarm connector pin assignments are as follows:
AJ1 and AJ2 Connector Pin Assignments
Pin Number
Signal Function
1
Relay A, Pin 1
2
Relay B, Pin 1
3
LINK
4
GND
5
GND
6
Relay A, Pin 2
7
Relay B, Pin 2
8
LINK
9
GND
Relay A is the major alarm relay. Relay B is the minor alarm relay. A relay is open when there is no
alarm. When a relay is closed, it indicates an alarm condition.
With power removed from the cabinet, both Relay A and Relay B are in the closed position (normally
closed), indicating an alarm condition.
Pins 3 and 8 are linked together to provide a loop. You can use this as a confirmation that an alarm cable
is installed. Pins 4, 5, and 9 are connected to cabinet ground. These pins can be jumpered to a relay
contact, if closure to ground is required.
Both Relay A and Relay B are rated at
48 Vdc maximum
0.5 A maximum
The link loop is rated at
12 Vdc maximum
200 mA maximum
Summary of Contents for Octel 200
Page 8: ......
Page 14: ......
Page 28: ......
Page 30: ......
Page 62: ......
Page 100: ......
Page 114: ......
Page 118: ......
Page 180: ......
Page 220: ......
Page 294: ......
Page 352: ......
Page 368: ......
Page 370: ......
Page 430: ......
Page 490: ......
Page 492: ......
Page 514: ......
Page 516: ......
Page 534: ......
Page 560: ......
Page 562: ......
Page 564: ......
Page 642: ......