4x4 HDMI2.0 Matrix with Audio Matrix
www.octavainc.com
770-825-0388
Command
Function
Feedback Example
yy=01~04 is the number of input port,
if the yy=00, it means all input ports.
/+[X]/[yy]:xxx.
Send serial data to local.
[X]= 1--2400
;
2--4800
;
3--9600
;
4-
-19200
;
5--38400
;
6--57600
;
7--
115200.
[yy] means the output port that sent
serial data, yy=01 means local
output.
xxx.
EDIDSTA[xx].
Query EDID status of Input port.
[xx]=00~04,
xx =01~04 is the number of input
port, if the xx =00, it means all input
ports.
Note:
⚫
If built-in EDID09 is not user-
defined, when querying it, the
input port will use EDID6 Internal
EDID instead. For example, send
"EDID/03/09.”, “EDIDSTA03.”,
and the result is “Input 03 EDID
From 06 Internal EDID!”.
⚫
If built-in EDID09 has been user-
defined, when querying it, the
input port will use the user-
defined EDID. For example, send
"EDID/03/09.”, “EDIDSTA03.”,
and the result is “Input 03 EDID
From User Define EDID!”.
⚫
If directly user-define the port
EDID, when querying it, the input
port will use the user-defined
EDID. For example, send
“EDIDSTA03.”, and the result is
“Input 3 EDID From User Define
EDID!”
Input 01 EDID From
01 Internal EDID!
Input 02 EDID From
01 Internal EDID!
Input 03 EDID From
01 Internal EDID!
Input 04 EDID From
01 Internal EDID!