15. CO2 START/STOP TIME
Press setting key, choose “CO2 START/STOP TIME”, press setting key, you will enter the CO2
START/STOP set time. Press setup key, you can set the CO2 start or stop time. After
confirmation, press the setting key and return to the main menu.
If not, please press ESC key.
CO2 Start time setup: 1-20mins
CO2 stop time setup: 1-20mins
All of the start and stop times are in the cycle time. set ON=5mins, OFF=5mins, controller will
show ON, CO2 start 5 mins and close 5 mins. When CO2 concentration reaches setup date,
CO2 will stop release, controller will show OFF.
When this cycle time is more than 40mins, the system will close the CO2 release. Controller
will show “OVERTIME”
16. FACTORY RESET
Press setting key, choose “FACTORY RESET”, press setting key, then choose “YES”. Press setting
key to confirm and return to the main menu, if not, please choose NO.
If not, please press ESC key.