OCL DLC-1.1 Manual Download Page 9

15. CO2 START/STOP TIME

 

 

Press setting key, choose “CO2 START/STOP TIME”, press setting key, you will enter the CO2 
START/STOP set time. Press setup key, you can set the CO2 start or stop time. After  
confirmation, press the setting key and return to the main menu.  
If not, please press ESC key. 

CO2 Start time setup: 1-20mins
CO2 stop time setup: 1-20mins 

All of the start and stop times are in the cycle time. set ON=5mins, OFF=5mins, controller will 
show ON, CO2 start 5 mins and close 5 mins. When CO2 concentration reaches setup date,  
CO2 will stop release, controller will show OFF. 

When this cycle time is more than 40mins, the system will close the CO2 release. Controller  
will show “OVERTIME” 

16. FACTORY RESET 

Press setting key, choose “FACTORY RESET”, press setting key, then choose “YES”. Press setting 
key to confirm and return to the main menu, if not, please choose NO. 
If not, please press ESC key.

Summary of Contents for DLC-1.1

Page 1: ...CONTROLLER MANUAL...

Page 2: ...nd crop damage The SHUTDOWN TEMP is an extra safety feature that will shut down all lighting in the room when the temperature is not reducing after the Auto Save Temp has set in Causes could be a malf...

Page 3: ...CLIMATE FOR YOUR PLANTS DEHUMIDIFIER 6 AUX HEATER DC INPUT 13V Max 1 5A Max TEMP RH CO2 AUX CO2 3 4 5 2 1 BOX CONTENTS 1 OCL DLC 1 1 Digital Lighting Controller 2 AC Adapter 240V 3 Temperature Sensor...

Page 4: ...nded to protect the sensor against radiation heat and place it in the shadow The CO2 sensor should be facing the light because of its light cell switching the sensor on day time and off night time Sin...

Page 5: ...key this will confirm the function and return to the main menu If not please press ESC key AUTO Auto save dimming function OFF Closed output ON Opened output 2 OUTPUT POWER Press setting key choose OU...

Page 6: ...d AUX room output opened 5 AUTO SAVE TEMP Press setting key choose AUTO SAVE TEMP press setting key you can change the setting AUTO SAVE TEMP with the up and down key Then press the setting key again...

Page 7: ...own key After confirmation press the setting key and return to main menu If not please press ESC key NONE closed this function 1 30 MIN Setting RISE FALL setting time to 10min power to 100 1000W when...

Page 8: ...alibrate 12 5 12 CO2 AUTO CALIBRATE Press setting key choose CO2 AUTO CALIBRATE before calibrate please put CO2 sensor to the outside bout for 5 minutes then choose YES press setting key again and ret...

Page 9: ...ins All of the start and stop times are in the cycle time set ON 5mins OFF 5mins controller will show ON CO2 start 5 mins and close 5 mins When CO2 concentration reaches setup date CO2 will stop relea...

Page 10: ......

Reviews: