982017-AIR-BASIC-Multitower-T201-EN01.docx
Page 37 of 60
7
Commissioning
7.1 Checks before commissioning
Material losses
Observe the maximum system temperature in
underfloor heating systems.
-
Check that the heating system is filled to the
correct pressure and the quick-action air vent
valve is closed.
-
Check whether the outside temperature
sensor is correctly placed and connected.
-
Check whether the power supply is connected
correctly.
-
Check whether the signal cable to the heat
pump (bus cable) is correctly connected.
7.1.1 High limit safety cut-out
NOTE
At temperatures below -15 °C the high
limit safety cut-out may respond. The
appliance may be subjected to these
temperatures
during
storage
or
transport.
-
Check whether the high limit safety cut-out
has tripped.
1
High limit safety cut-out reset button