E N G L I S H
1
Ocenco M-40 SCSR-S (Type D)
Self-Contained Self-Rescuer
CE 2849/EN 13794:2002
INSTRUCTION
BOOKLET
P/N 344455, DWG A16982
Rev. C, ECN 4091
The Ocenco M-40 SCSR-S is a belt worn or
stored, compressed-oxygen, self-contained self-
rescuer (Type D). The M-40 SCSR instantly
provides breathable air, independent of the
surrounding atmosphere, to a person escaping
from any area of toxic gas or oxygen deficiency.
The M-40 has a rated duration of 30 minutes in
accordance with EN 13794:2002. The “S” suffix
denotes the M-40 is designed and approved for
underground use.
DONNING PROCEDURE
The following are the donning steps for the belt
worn or stored configuration of the M-40 SCSR.
Warning:
These six steps must be practiced
numerous times until they become second
nature.
1.
Lift yellow lever and remove cover.
2.
Remove unit by pulling yellow strap upwards.