TO SET - WET ACTIVATION
Factory set for ON, Wet Activation can also be set OFF (dis-
abled) to prevent inadvertent activation during travel or storage.
When set ON, the Veo 100Nx will automatically Activate and
enter Dive Mode upon immersion in water.
• After having set and accepted the FO2 setting, the Set Wet
Activation screen appears with the Set Point flashing (Fig.
20).
- - or - -
• While the Surface Sequence is scrolling, depress the button
for 4 seconds to bypass Set FO2.
• Release the button when the Set Wet Activation screen
appears with the Set Point flashing.
• Press/release the button (less than 2 seconds) to toggle
between ON and OFF.
• Depress the button for 2 seconds to accept the Set Point and
advance to Set Units Of Measure.
Fig. 20 - SET WET
ACTIVATION