Oceanic ATOM 3.0 Operating Manual Download Page 28

28

ATOM 3.0 OPERATING MANUAL

© 2002 Design, 2011

Doc. No. 12-5216-r02 (9/6/11)

BAR GRAPHS

The ATOM features 2 specific bar graphs.

>  The one on the left represents nitrogen loading.  It is referred to as the TLBG (Tissue Loading Bar Graph).

>  The one on the right represents ascent rate.  It is referred to as the VARI (Variable Ascent Rate Indicator). 

TLBG (NORM/FREE)

The TLBG represents your relative No Deco (Fig. 83a) or Deco status (Fig. 84a).  The lower 4 segments represent No Deco status 

and the top one indicates a Deco condition.  

As your Depth and Elapsed Dive Time increase, segments add. 

As you ascend, segments recede indicating that additional No Deco time is available.  

The ATOM monitors 12 different nitrogen compartments simultaneously and the TLBG displays the one that is in control of your 

dive at any given time. 

VARI (NORM/GAUG)

The VARI (Fig. 85a) provides a visual representation of ascent speed (i.e., an ascent speedometer).

The segments represent two sets of speeds which change at a reference depth of 60 FT (18 M).  Refer to the chart.

When ascent is too fast, the audible will sound, and all VARI segments will flash (Fig. 86) until ascent is slowed.    

WARNING:  When deeper than 60 FT (18 M), ascent rates should not exceed 60 FPM (18 MPM).  At 

depths of 60 FT (18 M) and shallower, ascent rates should not exceed 30 FPM (9 MPM). 

ALGORITHM

The ATOM is configured with 2 algorithms which allows you to choose which set of NDLs (No Deco Limits) will be used for nitro-

gen/oxygen (Ni/O2) calculations and displays relating to Plan and Dive Time Remaining (DTR).

You can select to use either the DSAT or the PZ+.  The selection will lock in for 24 hours after the last dive.

DSAT has been the standard used by Oceanic in all of its dive computers until this time.  It features NDLs that are based 

on exposures and test data which also formed validation for the PADI RDP.  It imposes restrictions for repetitive Deco dives, 

considered more risky.

PZ+ (Pelagic Z+) performance is based on Buhlmann ZHL-16c.  It features NDLs that are considerably more conservative 

especially at shallower depths.

To create even greater margins of safety with respect to decompression, a Conservative Factor as well as No Deco Deep and 

Safety Stops can be included for No Deco dives.

CONSERVATIVE FACTOR (CF)

When the CF is set On, the allowable dive times, which are based on the algorithm selected and used for Ni/O2 calculations 

and displays relating to Plan and Dive Time Remaining, will be reduced to the values available at the altitude level that is 3,000 

feet (915 meters) higher.  Refer to the charts in the back of this manual for times.

DEEP STOP (DS), NORM No Deco only

When the DS selection is set On, it will trigger during NORM No Deco dives when you descend to 80 FT (24 M), then calculate 

(and continually update) a Stop Depth equal to 1/2 the Max Depth. 

 

While 10 FT (3 M) deeper than the calculated DS, you will be able to access a DS Preview screen that will display the current DS 

Stop Depth/Time.

Upon initial ascent to within 10 FT (3 M) below the calculated Stop Depth, a DS screen displaying a Stop Depth at 1/2 the Max 

Depth will appear with a Countdown Timer beginning at 2:00 (min:sec) and counting down to 0:00.

  

>  If you descend 10 FT (3 M) below, or ascend 10 FT (3 M) above, the calculated Stop Depth for 10 seconds during the 

countdown, the No Deco Main will replace the DS Main display and the DS feature will be disabled for the remainder of 

that dive.  There is no Penalty if the DS is ignored.

>  In the event that you enter Deco, exceed 190 FT (57 M), or a High O2 condition (=> 80%) occurs, the DS will be disabled 

for the remainder of that dive.

>  The DS is disabled during a High PO2 Alarm condition (=> Set Point).

Fig. 83 - NO DECO

Fig. 84 - DECO

a

a

Deeper than 60 FT (18 M)

VARI   

Ascent Rate

Segments 

FPM   

MPM

 

0 - 20   

0 - 6

 

21 - 30   

6.1 - 9

 

31 - 40   

9.1 - 12

 

41 - 50   

12.1 - 15

 

51 - 60   

15.1 - 18

 

60 + 

 

18 +

60 FT (18 M) & Shallower

VARI   

Ascent Rate

Segments 

FPM   

MPM

 

0 - 10   

0 - 3

 

11 - 15   

3.1 - 4.5

 

16 - 20   

4.6  - 6

 

21 - 25   

6.1 - 7.5

 

26 - 30   

7.6 - 9

 

30 + 

 

9 +

Fig. 85 - DIVE MAIN 

(Ascent normal)

Fig. 86 - DIVE MAIN

(Ascent Too Fast)

a

Summary of Contents for ATOM 3.0

Page 1: ...1 ATOM 3 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5216 r02 9 6 11 ATOM 3 0 DIVE COMPUTER OPERATING MANUAL...

Page 2: ...p 22 Set Algorithm NORM only 22 Set CF Conservative Factor NORM only 22 Set GLO Backlight Duration 22 Set SR Sampling Rate 22 Set TMT 1 2 3 23 SELECT DIVE OP MODE 24 HISTORY MODE NORM GAUG 24 SERIAL N...

Page 3: ...nterface Tissue Loading Bar Graph TLBG Pre Dive Planning Sequence PDPS Set Point Control Console Turn Gas Alarm OceanLog and Dual Algorithm are all registered and unregistered trademarks trade names a...

Page 4: ...4 ATOM 3 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5216 r02 9 6 11 Welcome to OCEANIC and THANK YOU for choosing the ATOM 3 0...

Page 5: ...5 ATOM 3 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5216 r02 9 6 11 FEATURES FUNCTIONS AND WATCH MODE...

Page 6: ...ed Violation EDT Elapsed Dive Time EL Elevation altitude F Temperature Imperial FA Free Alarm FO2 F Fraction of Oxygen FPM Feet Per Minute ascent rate FRE Free Dive Operating Mode FT Feet depth GAU Di...

Page 7: ...Surface Mode selections FREE Surface Mode selections Set NORM FO2 selections Set NORM GAUG Alarm selections Dive Computer Operating Mode selections Set Utility selections Set FREE Alarm selections Upo...

Page 8: ...s 51 to 60 FPM 15 1 to 18 MPM when deeper than 60 FT 18 M or 26 to 30 FPM 7 5 to 9 MPM at 60 FT 18 M and shallower FREE Dive Elapsed Dive Time Alarm 3 beeps every 30 seconds if set On FREE Dive Depth...

Page 9: ...erts to Watch Time Fig 3 until the Battery is changed or voltage cannot sustain operation 2 35 volts and the unit turns off ATOM 3 0 LOW BATTERY DURING A DIVE 2 75 volts warning level Backlight is com...

Page 10: ...ning Away is selected as Main Time blank if Home is Main Battery icon if a Low Battery voltage exists TLBG with icon if any after NORM or FREE dives M 2 sec to access NORM Surface Main A 2 sec to acce...

Page 11: ...o step back through selections S 2 sec to save the selection If OFF or ON is selected revert to the Lead in screen If SET is selected access the Set CDT screen S 2 sec to revert to CDT Lead in if no s...

Page 12: ...odes run in the background until set Off Daily Alarm Lead in information includes Fig 19 Graphics Go to and DAY AL S 2 sec to access Daily Alarm Status A 2 sec to step forward to Set T Lead in M 2 sec...

Page 13: ...r will be displayed at the top of the Watch Time screen when a Dual Time differential is set and Show Dual Time is set for YES Graphics SEL and dFLt Set Point graphic HOME or AWAY flashing A or M 2 se...

Page 14: ...2 sec to step back through Set Points S 2 sec to save the Month Set Point and flash the Day digits S 2 sec to step back to Set Year A hold to scroll upward through Day Set Points 8 sec from 1 to 31 m...

Page 15: ...15 ATOM 3 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5216 r02 9 6 11 NORM SURFACE MODES...

Page 16: ...evert to Main No button action 2 min revert to Main L press to activate the Backlight Various descriptions that follow as labeled apply to GAUG as well as NORM NORM SURF ALT 1 information includes Fig...

Page 17: ...to FLY PLAN MODE NORM only Dive time calculations in Plan Mode are based on the algorithm selected DSAT or PZ the FO2 value set for Gas 1 the default used for Plan the setting for the Conservative Fac...

Page 18: ...from the most recent to the oldest recorded 8 sec M 2 sec to step back through Preview screens S 2 sec to access Data 1 for the dive displayed S 2 sec at any time to revert to Log Lead in Log Data 1...

Page 19: ...ox When FO2 for any Gas is set for a numerical value 21 to 100 the dive is considered Nitrox with the NX icon displayed on all applicable screens Once FO2 for Gas 1 is set for a numerical value 21 to...

Page 20: ...Points M 2 sec to step back through Set Points S 2 sec to save the setting and access Set TLBG Alarm S 2 sec if no change to revert to Set Depth Alarm Set TLBG Alarm NORM information includes Fig 53...

Page 21: ...o Select DIVE OP mode M 2 sec to step back to SET A S 2 sec to access Set Wet Set Wet Activation information includes Fig 59 Graphics SEt and WET Set Point graphic ON or OFF flashing A or M 2 sec to t...

Page 22: ...wed time values The setting locks in for 24 hours after NORM dives Set CF Conservative Factor NORM information includes Fig 64 Graphics SEt and CF with icon Set Point graphic ON or OFF flashing A or M...

Page 23: ...operation advances to Set TMT 2 If SN is selected the Set TMT 1 SN screen is displayed Set TMT 1 SN Link Code information includes Fig 68 Graphics SEt and TMT1 SN with Tank 1 icon Serial Number Link...

Page 24: ...ig 76 Graphic SEA or EL2 to EL7 highest Altitude at which a dive was conducted Max Depth recorded to 330 FT 100 M with MAX and FT or M icons Longest dive time recorded during a single dive up to 599 m...

Page 25: ...Battery icon if Low 2 75 v flashing if 2 50 v TMT Status information includes Graphics bAtt and Good or LOW Fig 80 Tank Pressure with PSI or BAR Link and Tank 1 or 2 3 icons if the TMT is active and...

Page 26: ...26 ATOM 3 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5216 r02 9 6 11 DIVE MODE FEATURES...

Page 27: ...ively receive a signal when it is held out to the sides of the TMT or held at distances greater than 4 feet 1 2 meters in front of the TMT Best reception is achieved when the ATOM is within 3 feet 1 m...

Page 28: ...Z Pelagic Z performance is based on Buhlmann ZHL 16c It features NDLs that are considerably more conservative especially at shallower depths To create even greater margins of safety with respect to de...

Page 29: ...allowable nitrogen level Whichever one is closest to this maximum level is the controlling compartment for that depth Its resulting value will be displayed numerically as NDC time remaining Fig 87a an...

Page 30: ...30 ATOM 3 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5216 r02 9 6 11 NORM DIVE MODES...

Page 31: ...trox Revert to Main in 5 sec if A is not pressed L press to activate Backlight No Deco Alt 2 only if Nitrox information includes Fig 95 O2 accumulated with O2 icon This is the of the per dive or per d...

Page 32: ...eper than or equal to the required stop depth indicated and decompress for the stop time indicated The amount of decompression credit time that you receive is dependent on depth with slightly less cre...

Page 33: ...op Depth for more than 5 minutes operation will enter DV1 which is a continuation of CV with penalty time still being added The audible will sound and the full TLBG will flash Fig 106 until it is sile...

Page 34: ...screens The Fly countdown indicates time remaining before normal operation can resume with full features and functions HIGH PO2 NORM ONLY Warning at Alarm Set Point value minus 0 20 1 00 to 1 40 Alarm...

Page 35: ...th O2 icon will alternate with the graphic UP until on the surface Fig 116 The full TLBG remains on solid as a reminder of Deco S 2 sec to acknowledge silence alarm A 2 sec to access ALTs similar to t...

Page 36: ...36 ATOM 3 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5216 r02 9 6 11 GAS TMT SWITCHING...

Page 37: ...TMT selected If the Gas TMT are not switched to the same tank being used ATR will increase to maximum after 1 minute without a change in Pressure Gas Switch Warning If the switch to a new Gas would r...

Page 38: ...38 ATOM 3 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5216 r02 9 6 11 DIGITAL GAUGE OP MODE...

Page 39: ...EDT and min icons Graphic LAST indicating data is for dive previously conducted while still in GAUG mode Dashes if no previous dive conducted A 2 sec to step forward to ALT 2 M 2 sec to step back to M...

Page 40: ...e Surface Main and full access will be given to GAUG Surface items If a descent is made to 5 FT 1 5 M for 5 seconds the dive will be continued Surface time will not be added to Dive Time Once a dive i...

Page 41: ...41 ATOM 3 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5216 r02 9 6 11 FREE DIVE OP MODE...

Page 42: ...Graphic LAST indicating data is for previous FREE dive Dashes if no previous dive conducted while in FREE mode A 2 sec to step forward to ALT 2 M 2 sec to step back to Main FREE SURF ALT 2 informatio...

Page 43: ...DT ALARM Factory set for a fixed 30 seconds the EDT Elapsed Dive Time alarm sounds the audible every 30 seconds while underwater in FREE Dive Mode Set EDT Alarm information includes Fig 141 Graphics S...

Page 44: ...999 min with icon if set On Temperature with icon and graphic F or C TLBG with icon PZ CF icons if they apply A 2 sec to access ALT L press to activate Backlight Upon ascending to 2 FT 0 6 M during a...

Page 45: ...he Depth digits flashing on the Main Fig 149 High Nitrogen Alarms When nitrogen increases to the caution level 4 TLBG segments the audible will sound during which time the TLBG segments will flash on...

Page 46: ...46 ATOM 3 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5216 r02 9 6 11 REFERENCE...

Page 47: ...LEANING Protect your unit from shock excessive temperatures exposure to chemicals and tampering Protect the lens against scratches with a Instrument Lens Protector Small scratches will naturally disap...

Page 48: ...r sealing O ring replacement is highly recommended each time the Battery is replaced Closely examine the threads of the Battery Cover and Housing for any signs of damage that might prevent proper thre...

Page 49: ...r Since a user has the option of alternating between SCUBA and Free Dive activities within a 24 hour period nitrogen calculations and the displayed value of No Deco Dive Time Remaining NDC time are ca...

Page 50: ...50 ATOM 3 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5216 r02 9 6 11 TECHNICAL DATA...

Page 51: ...4 4 4 4 48 6 5 5 4 4 4 4 4 4 3 3 3 51 5 4 4 4 4 4 4 3 3 3 3 3 54 5 4 4 4 4 3 3 3 3 3 3 3 57 5 4 4 3 3 3 3 3 3 3 3 3 DSAT ALGORITHM NDLS minutes at ALTITUDE Imperial Altitude 0 3001 4001 5001 6001 700...

Page 52: ...ving after 24 hours with no dives Dive Log Mode Stores 24 most recent NORM GAUG dives in memory for viewing After 24 dives adds 25th dive in memory and deletes the older dive Altitude Operational from...

Page 53: ...NUED WARNING If your ATOM 3 0 stops working for any reason while operating as a Dive Computer it is important that you have anticipated this possibility and are prepared for it This is an important re...

Page 54: ...________________________________________ Purchased from ___________________________________________________________________________________________________ Below to be filled in by an Authorized Ocean...

Page 55: ...55 ATOM 3 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5216 r02 9 6 11 NOTES...

Page 56: ...56 ATOM 3 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5216 r02 9 6 11 ATOM 3 0 DIVE COMPUTER OPERATING MANUAL...

Reviews: