Oceanic Sauna Heater
16
Chapter Five: Trouble shooting Guide
Please Note that we recommend a suitably qualified person carries out all repairs.
Trouble description
Cause
Solutions
There is no display on
the control panel when
the on/off switch is
pressed
There is a problem with;
1.power supply or
2.circuit board transformer or
3.fuse
1. Check the power supply. If the power
supply indicator LED L1 (red) is on, check
the wire
2. Change the controller
The controller is on but
the sauna heater
doesn’t work
1. The sauna heater hasn’t
been connected
2. There is a problem with the
controller
1. Check the connection, refer to (Fig 2 and
Fig 10)
2. Change the controller
High1 LED is on
1. The temperature sensor
hasn’t been connected
correctly
2. The high temperature cut
off switch is turned off
1. Check the connection to temperature sensor
2. Check if the high temperature cut off
switch is turned off, if yes ,reset by hand
Wait LED is on
Sauna heater is under B
model
Press the Model button to change to A
model (heating Mode)
Temperature windows
display --L (or
)or --H (or )
1. Thermometer isn’t
connected or cable is
broken
2. The temperature is lower
than 0
o
C (or 32
o
F),
The temperature is higher
than 115
o
C (or 239
o
F)
1. – L
o
C (or
o
F) means temperature sensor
hasn’t connected or the temperature is
lower than 0
o
C (or 32
o
F), check the
connection, cable or change sensor
2. – H
o
C (or
o
F) means there is a short circuit
in the temperature sensor or the
temperature is higher than 115
o
C (or
239
o
F) check the connection, cable or
change sensor
3. Change controller