background image

6

7

TECHNICAL SUPPORT

If you require technical support for any Oceanic Systems products you can reach us using any of 

the following:-

 

 Tel:  +44(0)1425 610022

 

 Fax: +44(0)1425 614794

 

 Email: [email protected]

 

 Web:   www.osukl.com

 

 Post:   Oceanic Systems (UK) Ltd

                          Unit 10-11 Milton Business Centre

                           Wick Drive, New Milton, Hampshire BH25 6RH

Oceanic Systems (UK) Ltd

Unit 10-11 Milton Business Centre, Wick Drive,

New Milton, Hampshire, BH25 6RH, United Kingdom

Tel: +44(0)1425 610022        Fax: +44(0)1425 614794

Email: [email protected]           Web: www.osukl.com

Copyright © 2018 Oceanic Systems (UK) Ltd. All rights reserved. Our policy is one of continuous product improvement so product 

specifications  are  subject  to  change  without  notice.  Oceanic  Systems  products  are  designed  to  be  accurate  and  reliable. 

However, they should be used only as aids to vessel monitoring, and not as a replacement for traditional navigation and vessel 

monitoring techniques. NMEA2000® is a registered trademark of the National Marine Electronics Association.

Please note that below are some FAQ/Troubleshoot Questions. If none of these help or apply, 

then please don’t hesitate to contact Technical Support.

Blue LED not flashing

Check NMEA2000® network cable connection and 

network power

Device not switching relays on command

Check Device Instance Switches match the settings 

required by the control device

Green LED indicates relay operated but device 

connected to the relay output not operating

Check wiring of device

8

TROUBLESHOOTING/FAQ

Summary of Contents for 5980

Page 1: ...Whistle Operating Module Part Numbers 5980 USER MANUAL Document revision 1 00 0 F E D C B A987 6 5 4 3 2 1...

Page 2: ...etup instructions carefully to achieve the best results 1 1 PRODUCT FEATURES The 5980 Whistle Operating Module has the following features 2 Fully Isolated 1 Amp ships Horn or Whistle Relays with norma...

Page 3: ...unit is connected to the NMEA2000 network by the 5 way micro C socket on the front Carefully attach the network drop cable to this plug and hand tighten until it is fully seated Take care to match th...

Page 4: ...ck The wire should be stripped for 8mm and then the cage clamp opened with a small screwdriver in the slot above the wire connection Then simply insert the wire into its connection slot and release th...

Page 5: ...e paint or markings or may corrode the enclosure or seals Ensure that the unit is mounted securely and cannot be moved relative to the mounting surface If the unit is loose tighten the mounting screws...

Page 6: ...DC Voltage Power Consumption 300mA Average Operating Load Equivalence Number 1 Indefinitely Reverse Battery Protection Yes Indefinately Load Dump Protection Yes SAE J1113 Size 117mm x 6omm x70mm Weigh...

Page 7: ...uct specifications are subject to change without notice Oceanic Systems products are designed to be accurate and reliable However they should be used only as aids to vessel monitoring and not as a rep...

Page 8: ...IAL DAMAGES DAMAGES FOR LOSS OF USE LOSS OF ANTICIPATED PROFITS OR SAVINGS OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE IN NO EVENT SHALL OCEANIC SYSTEMS AGGREGATE LIABILITY EXCEED TH...

Reviews: