NMEA2000® AC MONITOR
Part Numbers: 3420
USER MANUAL

Revision 1.00

Summary of Contents for 3420

Page 1: ...NMEA2000 AC MONITOR Part Numbers 3420 USER MANUAL Revision 1 00 ...

Page 2: ...ng the unit 3 2 3 Connecting the NMEA2000 Cable 3 2 4 Connecting the Voltage Current Transformer Input Cables to Deutsch Connector 4 2 5 Deutsch Connector Pinout 4 3 Configuration 5 3 1 NMEA Device Instance 5 3 2 Device Circuit Type 5 3 3 NMEA2000 Parameter Group Functions PGNs 10 4 Warranty 12 5 Technical Support 13 ...

Page 3: ...d follow the installation and setup instructions carefully to achieve the best results 1 1 FIRMWARE REVISION The information in this manual corresponds to firmware revision 1 00 1 2 PRODUCT FEATURES The NMEA2000 3420 AC Monitor has the following features Inputs for AC Voltage 300 VAC MAX Inputs for 200 Amp AC Current Transformers User Settable Circuit Type Heartbeat LED Confirming NMEA Transmissio...

Page 4: ...o be water resistant it should be mounted away from sources of condensation and moisture 2 3 CONNECTING THE NMEA2000 CABLE The unit is connected to the NMEA2000 network by the 5 way micro C socket on the front Carefully attach the plug of the network drop cable to this socket and tighten by hand until it is fully seated Take care to match the orientation of the pip inside the socket to the recess ...

Page 5: ... be stripped and crimped with matching socket crimps PN 5099 Male Deutsch Adaptor Kit Connections to a mating Deutsch socket housing should be made as in the following table 2 5 DEUTSCH CONNECTOR PINOUT WARNING Unit must be installed by a qualified electrical engineer Incorrect connections may result in damage to the unit PERSONAL INJURY or DEATH Terminal 1 Voltage Phase C Line Terminal 2 Neutral ...

Page 6: ...instance when purchasing The following items can be configured on the 3420 Attributing the device can be configured using the xxxx configurement unit Which can then be connected to the interface Please contact Oceanic Systems for further details 3 1 NMEA DEVICE INSTANCE You can select a unique device instance up to 254 The data instance will match the device instance Data instances and device inst...

Page 7: ...URRENT PHASE A 1 VOLTS PH C 2 VOLTS NEUTRAL 3 NOT CONNECTED 4 CURRENT PHASE C 5 CURRENT PHASE B 6 CURRENT PHASE A 1 2 3 4 5 6 7 8 9 10 11 12 Line Phase A Neutral Fuse U S 120 Volts 60Hz Europe 220 Volts 50Hz Black Red This must be configured with one of the methods outlined in 3 before the device can be used ...

Page 8: ... 1 VOLTS PH C 2 VOLTS NEUTRAL 3 NOT CONNECTED 4 CURRENT PHASE C 5 CURRENT PHASE B 6 CURRENT PHASE A 1 2 3 4 5 6 7 8 9 10 11 12 Line Phase A Line Phase B Neutral Fuse U S 120 Volts 60Hz Europe 220 Volts 50Hz Fuse Black Red Black Red This must be configured with one of the methods outlined in 3 before the device can be used ...

Page 9: ...CONNECTED 4 CURRENT PHASE C 5 CURRENT PHASE B 6 CURRENT PHASE A 1 2 3 4 5 6 7 8 9 10 11 12 Line Phase C Line Phase A Line Phase B Neutral Fuse U S 120 Volts 60Hz Europe 220 Volts 50Hz Fuse Fuse Black Red Black Red Black Red Three Phase Connection This must be configured with one of the methods outlined in 3 before the device can be used ...

Page 10: ...A 1 VOLTS PH C 2 VOLTS NEUTRAL 3 NOT CONNECTED 4 CURRENT PHASE C 5 CURRENT PHASE B 6 CURRENT PHASE A 1 2 3 4 5 6 7 8 9 10 11 12 Line Phase A Line Phase B Neutral Fuse U S 120 Volts 60Hz Europe 220 Volts 50Hz Fuse Black Red Black Red This must be configured with one of the methods outlined in 3 before the device can be used ...

Page 11: ...nge the frequency will be transmitted as 49 9Hz Type PGN No PGN Name Monitor PGN 127744 AC Power Current Phase A PGN 127745 AC Power Current Phase B PGN 127746 AC Power Current Phase C PGN 127747 AC Voltage Frequency Phase A PGN 127748 AC Voltage Frequency Phase B PGN 127749 AC Voltage Frequency Phase C Protocol PGN126464 Tx Rx PGN List PGN126996 Product Information PGN126998 Configuration Informa...

Page 12: ...nately Load Dump Protection Yes SAE J1113 Size mm 123 x 104 x 47 Weight gr 350 Parameter Value IEC 60954 Classification Protected Degree of Protection IP64 Operating Temperature 25 C to 50 C Storage Temperature 40 C to 70 C Relative Humidity 93 RH 40 per IEC60945 8 2 Vibration 2 13 2Hz 1mm 13 2 100Hz 7m s2 per IEC 60945 8 7 Electromagnetic Emission Conducted and Radiated Emission per IEC 60945 9 E...

Page 13: ...TIAL DAMAGES DAMAGES FOR LOSS OF USE LOSS OF ANTICIPATED PROFITS OR SAVINGS OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE IN NO EVENT SHALL OCEANIC SYSTEMS AGGREGATE LIABILITY EXCEED THE PURCHASE PRICE OF THE PRODUCT S INVOLVED OCEANIC SYSTEMS SHALL NOT BE SUBJECT TO ANY OTHER OBLIGATIONS OR LIABILITIES WHETHER ARISING OUT OF BREACH OF CONTRACT OR WARRANTY TORT INCLUDING NEGLIGENCE...

Page 14: ...New Milton Hampshire BH25 6RH United Kingdom Tel UK 44 0 1425 610022 Tel USA 844 898 6462 Fax 44 0 1425 614794 Email sales osukl com Web www osukl com Copyright 2022 Oceanic Systems UK Ltd All rights reserved Our policy is one of continuous product improvement so product specifications are subject to change without notice Oceanic Systems products are designed to be accurate and reliable However th...

Page 15: ......