
© Copyright 2008, 2011 Undersea Systems International, Inc., dba
Ocean Technology Systems.
All rights reserved. Specifications are subject to change without prior notice.
All users must fully understand the contents of these instructions before use of the product.
MAG-1001S AND STX-101 UNITS:
.We recommend the connection first be made between the panel’s 12-volt
Power/CHG jack (Figure 3;
see arrow
) and the RCS-13 charger. Then plug the charger into your power source.
Charging time for a depleted battery is 3–5 hours. You do not need to remove the front panel to charge the batteries.
Anytime you charge the batteries, open the front panel’s “Battery Charging Relief Valve.” Leave it open and do not
operate the MAG-1001S or STX-101 unit for at least 15 minutes after charging, to give the system time to dissipate
any gasses released from the batteries during charging. After charging is complete, close the “Battery Charging
Relief Valve.”
Figure 3: MAG-
1001S Front Panel
(STX-101 is same
configuration for
charging)
MK2-DCI:
To recharge the RB-6V batteries, you need not remove them from the MK2-DCI. Just connect the RCS-
13 universal smart battery charger to the front-panel
12-volt external power jack
(Figure 4;
see arrow
). Then connect
the charger’s power plug
to any 90-260–volt, 60-cycle power outlet. Do not use unit for 20 minutes after charging is
complete, to give the system time to dissipate any gasses released (as in the MAG-1001S and STX-101 shown above).
Figure 4: MK2-
DCI Front Panel