506128-000 (B)

Operation Instructions for the

RCS-13 Smart Battery Charger

Ocean Technology Systems

  •  

3133 W. Harvard Street, Santa Ana, CA  92704  USA

Toll-free: (800) 550-1984  •  Tel.: (714) 754-7848  •  Fax: (714) 966-1639  •  [email protected]  •  www.otscomm.com

The RCS-13 smart charger is a universal-input, lead-acid battery charger for rapid charging of the RB-6V batteries 

used in various Ocean Technology Systems (OTS) com-

munications products, such as the Aquacom

®

  MK2-DCI 

surface intercom, the Aquacom

®

 STX series of surface 

transceivers, and the Magnacom

®

 MAG-1001S surface 

transceiver. By following the simple instructions pro-

vided here, you should experience long-term, trouble-free 

use of your RCS-13 charger.
The RCS-13 charger consists of the charging module and 

power output cord as one unit (Fig. 1). The power output 

connectors are mini banana connectors. A power input 

cord is provided with your choice of plugs depending on 

the region of the world where the charger will be used.

OPERATION                                                              

1. Connect the 

power output connectors

 (mini banana plugs) (Fig. 1) to the communications unit

 as described on the 

back of this instruction sheet.

2. Connect the 

power input connector 

to the 

charging module

 and the 

power input plug

 to the AC source.

3. Once the connections are made, the charger will determine 

the battery condition before starting to charge the battery. The 

LED on the 

charging module

 indicates the charging status 

(Table 1).
If the battery does not hold a charge after repeated charging 

attempts, the battery may need replacement. (Replacement 

RB-6V batteries are available from OTS or your local dealer.)

4. When the LED indicates “standby/ready” status (Table 1), 

charging is complete. Unplug the charger from the AC power 

source and the battery or communications unit.

IMPORTANT SAFETY NOTES                               

1. Do not attempt to charge alkaline or other non-rechargeable batteries. Doing so may damage the batteries and 

the charger.

2. Keep the charger away from water and dust.
3. The charger should remain uncovered and properly ventilated while in use.
4. Use the charger only with the batteries for which it was intended. If you have any questions about the batteries 

with which the RCS-13 should be used, contact us.

Table 1: Charging status as indicated by LED

Figure 1: Charging unit and power input cord

Green

No battery connected

 Red

Fast charge cycle

 Red

Top-off charge cycle, constant 

voltage

Green

Standby/Ready (charge cycle 

complete)

Mode

LED