7 - TROUBLESHOOTING

Problem

Probable cause

What to do  

The surface 

unit does not 

turn on

1.  Low battery

1.  Recharge the batteries

The 

underwater 

unit does not 

receive

1. 

Power turned off

2.  The surface diver cable 

is not attached to the 

surface unit

3.  Low volume

4.  Flooded underwater unit

1.  Turn on the surface unit

2.  Check the surface unit 

connection

3.  Turn up volume

4.  Return to surface, rinse in fresh 

water and send to OCEAN 

REEF service center

Surface is not 

receiving 

1. 

Volume too low

2. 

Power turned off

3.  Flooded microphone on 

underwater unit

4. 

Flooded UW unit

1.  Raise volume on the surface 

audio and check the power

2.  Turn on the surface unit

3.  Return to surface, rinse in fresh 

water, replace mic

4.  Return to surface, rinse in fresh 

water and send to OCEAN 

REEF service center

Recall system

1.  Issues with the 

underwater unit button

2.  Issues with the surface 

unit alarm system

1.  Return to surface, rinse in fresh 

water and send to to OCEAN 

REEF service center

2.  Return to surface and send to 

OCEAN REEF service center

Replacing the Mic

Remove the MIC assembly from the mask, unscrew few threads of the two little side screws 

and pull off the Mic. Replace with the new one being careful not to overtighten the little 

screws to avoid damages to the contacts and to mount the microphone in the same direction.

Summary of Contents for ALPHA-PR0 X-DIVERS

Page 1: ...ALPHA PR0 X DIVERS OWNER S MANUAL...

Page 2: ...ITIES 3 TIPS REMINDERS FOR USE 4 FEATURES AND COMPONENTS PACKAGE CONTENTS 4 1 SURFACE UNIT 4 2 PROFESSIONAL SURFACE DIVER CABLE 4 3 UNDERWATER UNIT 2 0 5 MOUNTING THE UNDERWATER UNIT 2 0 6 DIVER MODE...

Page 3: ...will not accept liabilities for any damage caused by Insufficient incorrect and improper maintenance failing to comply with the manual s recommendations Absence of periodic tests and checks Incorrect...

Page 4: ...right to modify any products processes and manufacturing techniques at any time It is the technicians responsibility to acquire the latest information and parts from OCEAN REEF for service and repairs...

Page 5: ...or repair the communication unit by yourself Before charging please make sure the charging port is dry Charge in a safe dry place When not in use or at the end of each use make sure that the surface u...

Page 6: ...hat cannot compromise on a full duplex hands free clear communication system Cable communication is still unequaled in quality while needing a tethered connection of a diver to the surface The underwa...

Page 7: ...diver 1 surface diver 2 surface diver 1 diver 2 cross talk 5 Headset port headset optional 6 Battery charger external power audio out port cables optional 7 Audio video recall 8 Incorporated speaker 1...

Page 8: ...y attaching a small buoy or floating device to the cable a few feet away from the underwater unit It is a good idea to connect the cable with a hook or retractor to the BC jacket avoiding any traction...

Page 9: ...unit can be disconnected and connected again underwater Routinely clean the microphone contacts and check the integrity of the hydrophobic membrane and the casing If the microphone is flooded it CANNO...

Page 10: ...he one connected to the mic PTT earphone of the ALPHA PRO X DIVERS underwater unit securing it to the Extender Frame exactly like a neutral or an earphone support Bridges have L and R written on them...

Page 11: ...n the COMMUNICATION side port of the mask by screwing it on The crown around the PTT will turn until flush Last connect the R earphone to the right side of the Extender Frame by having the cable conne...

Page 12: ...1 Diver 2 Surface Diver 2 Surface Diver 2 Diver 1 Surface Diver 1 Surface DIVER 1 SELECTED Receive from Talk to Surface Diver 1 2 Diver 1 Diver 1 Diver 2 Surface Surface Diver 2 None Diver 1 Surface...

Page 13: ...underwater unit 4 Flooded UW unit 1 Raise volume on the surface audio and check the power 2 Turn on the surface unit 3 Return to surface rinse in fresh water replace mic 4 Return to surface rinse in...

Page 14: ...uch as diluents to clean the unit They can cause irreparable damage Only use neutral detergents Do not expose the unit to direct sunlight for prolongued periods of time TYPE OF ACTION FIRST USE BEFORE...

Page 15: ...used by the product falling after it was purchased Damage caused by fire earthquake floods lightning or other natural disasters The warranty card is not produced Your name the date of purchase and the...

Page 16: ...9525 E mail operator oceanreefgroup com MESTEL Safety s r l Via Arvigo 2 16010 Genova Italia Phone 39 010 7082011 E mail infoitaly oceanreefgroup com diving oceanreefgroup com oceanreefgroup com ACCE...

Reviews: