Summary of Contents for OMX-07HMHM0001

Page 1: ......

Page 2: ...any source to up to four connected HDMI displays This HDMI 2 0 unit supports up to 4K 60Hz with flexible switching options for ease of use as well as digital and analog audio extraction The OMX 07HMHM...

Page 3: ...hoose one input workable only if output is already choosen press and hold to choose one input for all outputs PRESET PRESS TO ACCESS PRESETS UP Button LOCK Press and hold to lock repeat to unlock When...

Page 4: ...tional Connect an ethernet cable from the TCP IP port on the matrix to a local network Connect 12V power supply to DC power socket Power on the matrix HDMI sources and displays 1 2 3 4 5 6 Operating I...

Page 5: ...CD screen will show System Shutdown HDMI output 5V will disconnect and TV without image Press again to wake device HDMI output will return to normal Video Switch output input ex output 1 input 2 switc...

Page 6: ...nel outputs Operation format Output channel input channel or press and hold input channel Video Switch Operation Operating Instruction Panel Control Description There are 2 sub menus in video interfac...

Page 7: ...and down button to select On Off Press Enter button to enter the next sub menu Press up and down button to select output 1 4 Press Enter to enter the next sub menu Select Ouput HDMI 1 4 press Enter b...

Page 8: ...There are 2 sub menus in audio control interface Line out De Embed both are default open Audio Control Interface Operating Instruction...

Page 9: ...Ex to mute an HDMI connected to output1 press Audio Enter Line Out Output1 HDMI1 Off Enter Line out means switch HDMI output audio you are able to mute the TV from any one HDMI output channel Operatio...

Page 10: ...1 Press the Enter button to enter the next sub menu Press the up and down button to select Default1 press Enter to complete setting Behind the selected EDID it will show the max support resolution aud...

Page 11: ...then Enter Clear preset Clear and any presets 1 8 then Enter the saved preset will return to the default The Preset interface can save the current video audio EDID system settings etc supports 8 diff...

Page 12: ...button to select 9600 press Enter to complete setting Baud Rate Setting 4 options for baud rate setting 9600 19200 57600 115200 The default serial port is 115200 The below example is setting baud rat...

Page 13: ...Reboot device default is NO Operation 1 2 3 4 5 Select Setup in main menu and press the Enter button Press the up and down button to select DHCP setting Press Enter to enter the next sub menu Press t...

Page 14: ...ame Ex factory all operation Select Setup in the main menu and press the Enter button Press the the up and down button to select Factory Press Enter to enter the next sub menu Press the up and down bu...

Page 15: ...ll turn white when selected Press Enter to enter the next sub menu then you are able to query device information System interface query company name device name and version information IP interface qu...

Page 16: ...Operating Instruction...

Page 17: ...pen command format fields receiving command the system will Example1 Type Command head Explain Format cmd without cmd Search all open command Value Choose correct COM port that connect to PC in parame...

Page 18: ...he device are set in the same network segment 1 Open the network control center and set the computer s IP address 2 Choose to use Static IP with the IP address set to 196 168 1 x x ranges from 0 to 25...

Page 19: ...l the preset Save save the preset Operation steps 1 Call preset preset1 Recall call preset1 2 Save preset preset2 Recall save preset2 Default IP address for log in 192 168 1 168 Type in user name and...

Page 20: ...ff HDMI output1 audio extraction Click output1 De Embed color will change and audio for analog and SPDIF out will turn off Re click to turn on audio 1 Click output1 4 HDMI Turn off HDMI output audio O...

Page 21: ...ow EDID here click 00 Input1 or 00 Default1 will show resolution audio audio channel HDR and serial number Edit user EDID Click Edit User EDID choose default user copy input EDID on EDID Edit Page to...

Page 22: ...l re login into the web interface If unable to refresh automatically then resubmit form manually Dynamic IP Click DHCP switch DHCP On IP address is assigned by router and will turn to grey can not be...

Page 23: ...pports 6 15 characters Reboot Click to reboot device Factory Common Click to reset device for partial function Factory All Click to reset device totally Reboot will not clear user parameter Factory Co...

Page 24: ...ical shock and injury to persons To prevent fire or shock hazard do not expose the unit to rain moisture or install this product near water Never spill liquid of any kind on or into this product Never...