Setup 

Overview 

Before using the HL-2000 for the first time, check for transport damage. Be sure to adhere to all warnings on the unit and in this 
manual. 

There are 4 versions of light sources in the HL-2000 family.  These are outlined below.  Only the FHSA versions have the DB15 
connector, associated cable, shutter switch, and attenuator. 

 

 

 

 

Long Lifetime (LL) 

High Power (HP) 

 

 

The LL light sources employ a 
unique long lifetime lamp that 
extends operation to 10,000 hours. 

With a 20W nominal bulb power, 
the HP sources provide 5X the 
output of the LL models but at a 
fraction of the operation lifetime. 

 

No Shutter 

HL-2000-LL 

HL-2000-HP 

FHSA

 

The FHSA versions have a 
DB15 connector allowing for 
an external source to control 
the shutter. 

HL-2000-FHSA-LL 

HL-2000-HP-FHSA 

 

 

 

Summary of Contents for HL-2000-LL

Page 1: ...HL 2000 Tungsten Halogen Light Source Installation and Operation Manual Products HL 2000 LL HL 2000 FHSA LL HL 2000 HP HL 2000 HP FHSA...

Page 2: ......

Page 3: ...ise without written permission from Ocean Insight This manual is sold as part of an order and subject to the condition that it shall not by way of trade or otherwise be lent re sold hired out or other...

Page 4: ...perating environment 2 Dangerous voltages are present in this device There are NO user serviceable parts inside 3 Only allow Ocean Insight qualified personnel to service this unit 4 Do not use the uni...

Page 5: ...e DB15 connector associated cable shutter switch and attenuator Long Lifetime LL High Power HP The LL light sources employ a unique long lifetime lamp that extends operation to 10 000 hours With a 20W...

Page 6: ...ent in a clean laboratory environment Contents Your HL 2000 package should contain the following HL 2000 Light Source Power Cable FHSA models only o One IC DB15 2 interface cable for shutter operation...

Page 7: ...High Open Low Closed Optimizing the Optical Power Output The HL 2000 is adjusted at the factory to provide maximum power into a 200 m fiber If a lower optical power is required or a different fiber bu...

Page 8: ...ear of the unit is in the open position 2 Loosen the fixture screw with the provided 2 0 mm Allen wrench 3 Turn the attenuation screw until the desire optical power is achieved 4 Tighten the fixture s...

Page 9: ...fetime 10 000 Hrs typical 1 000 Hrs typical Fiber Connector SMA 905 Shutter No Yes No Yes DB 15 Connector No Yes No Yes Bulb color temperature 2 800 K 3 000 K Operating temperature 5 C 35 C Humidity 5...

Page 10: ...arts Order Information Catalog Number Halogen spare bulb 2 800K 10 000 hrs HL 2000 B LL Halogen spare bulb High Power HL 2000 HP B Pin Description Pin Description 1 na 9 na 2 na 10 Ground 3 na 11 na 4...

Page 11: ...board from the unit taking care not to disconnect the fan wires 4 Loosen the bulb fixture screw from the bottom of the unit with the provided 1 3 mm Allen key 5 Disconnect the wires from the connecti...

Page 12: ...Questions Chat with us at OceanInsight com info oceaninsight com US 1 727 733 2447 EUROPE 31 26 3190500 ASIA 86 21 6295 6600...

Reviews: