background image

During this function, the display will show the actual

room temperature, not the set temperature as in the

cooling mode.

TO USE THE ENERGY
SAVER FEATURE:

Press the button

Auto
Cool

Dry
Fan 

Low

Auto

Med
High

Clean

   Air

Fan 

Mode

Follow

   Me

Energy

  Saver

On/Off

DO THIS:

This function is available on COOL mode.The fan 

will continue to run for 3 minutes after the compressor

shuts off.The fan then cycles on for 2 minutes at 10 

minutes intervals until the room temperature is above 

the set temperature, at which time the compressor 

turns back on and cooling starts.

NOTE:

Temp

Temp

Timer

Timer

On
Off

Sleep

Check

Filter

Timer

Auto
Cool

Dry
Fan 

Low

Auto

Med
High

Clean

   Air

SLEEP FEATURE:

Press SLEEP

button

DO THIS:

In this mode the selected temperature will increase by

one degree, 30 minutes after the mode is selected.  

The temperature will then increase by another 

one degree after  an additional  30 minutes. This new 

temperature will be maintained for 6 hours before it 

returns to the originally selected temperature. This 

ends the Sleep mode and the unit will continue to 

operate as originally programmed. The Sleep mode

program can be cancelled at any time during operation 

by pressing the SLEEP button again.

NOTE:

7

To operate on DRY mode:

In this mode, the air conditioner will generally operate

 

as a dehumidifier. In a closed or sealed space, some

degree of cooling will continue.

In Fan only mode ,the temperature is not adjusted.

AIR CONDITIONER FEATURES(CONTINUED)

Summary of Contents for OBZ-06CR

Page 1: ...Before using this product please read the instructions carefully and keep for future reference MODEL OBZ 06CR OBZ 08CR www oceanbreezecomfort com...

Page 2: ...e that they do not play with the appliance If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard The applian...

Page 3: ...ck or fire due to heat generation This may cause electric shock This may cause failure of machine or electric shock This may cause fire and electric shock This may cause fire and electric shock Do not...

Page 4: ...unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified service technician 3 appliance or accident Appearance...

Page 5: ...ct Manufacturer Do not under any circumstances cut remove or bypass the grounding prong Power cord with 3 prong grounding plug and current detection device Operation of Current Detection Device Applic...

Page 6: ...ES ACTIVATES TIMER CHECK FILTER RESET BUTTON SETS MODE ENERGY SAVER MODE SLEEP MODE CLEAN AIR MODE only on some models SET FAN SPEED TURNS UNIT ON OR OFF UNIT CONTROL Temp Temp Timer Timer On Off Slee...

Page 7: ...PERATING MODE Press the MODE button Auto Cool Dry Fan Low Auto Med High Clean Air Fan Mode Follow Me Energy Saver On Off DO THIS To select mode press the Mode button Each time you press the button the...

Page 8: ...Dry Fan Low Auto Med High Clean Air SLEEP FEATURE Press SLEEP button DO THIS In this mode the selected temperature will increase by one degree 30 minutes after the mode is selected The temperature wil...

Page 9: ...MER OFF Press or hold the UP or DOWN button to change the then at 1 1 hour increments up to 24 hours T he control w ill will count down the time remaining until start The selected time will register i...

Page 10: ...mostat allowing for the precise temperature control at its location ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedure here are more features in your control that you...

Page 11: ...m sharp metal edges and aluminum fins on front and rear coils Top Rail Hardware 3 8 Screws 4 Top Rail 1 on the unit For 10000Btu h models only Tool Needed Phillips Screwdriver A Remove the air conditi...

Page 12: ...filter panels are on the proper side When installed the flange for securing the panel in place to the window sill should be facing into the room necessary for proper condensed water utilization and dr...

Page 13: ...ing screws through the frame lock and into the sill Fig 8 NOTE To prevent window sill from splitting drill 1 8 3mm pilot holes before driving screws 2 13mm 4 Fig 7 Fig 8 12 C Once the panel has been i...

Page 14: ...MIN 38 mm Sash Board thickness as required for proper pitch to rear along entire sill Fasten with nails or screws Fig 13 Removing AC From Window 13 Remove sash seal from between windows and unscrew sa...

Page 15: ...e replacing Or instead of washing you may vacuum the filter clean Note Never use hot water over 40 C 104 F to clean the air filter Never attempt to operate the unit without the air filter Cabinet Clea...

Page 16: ...ent may be touching the cold coil located behind the air filter Straighten the tube away from the coil The temperature may need to be set lower for the air conditioner to activate The compressor may h...

Page 17: ...d the unit initially Water dripping INDOORS when the unit is on COOL The air conditioner may have been improperly installed Tilt the air conditioner slightly outward to allow water to drain out Refer...

Page 18: ...Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Switching Sound Droplets of water hitting condenser during normal operation may...

Page 19: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...