System Requirements
45572-I
see copyright, disclosure, use and duplication information on pg. iii
2-5
406 cm
(160”)
91 cm
(36”)
600 cm
(236”)
Host
Computer
Air Hose
SCSI
Connector
Blower Hose
AC Power
Connector
LightJet 430
183 cm (72”)
Minimum Doorway
Dimension
Shaded Area Reserved
for Operations and Maintenance
(must be kept clear of obstructions)
91 cm
(36”)
3
28
c
m
(1
2
9
”)
1
52
c
m
(6
0
”)
1
60
c
m
(6
3
”)
15
c
m
(6
”)
Figure 2-4 Darkroom size requirements.
NOTE
The area around the machine must be kept clear of obstructions. Cables must be
managed to prevent tripping.
We recommend that the host computer reside in a room adjacent to the darkroom. This allows
host operation to continue during periods when the darkroom lights must be turned off for
media loading or unloading.
Electrical Requirements
AC Power
The LightJet
®
430 operates over the following range of voltages and frequencies:
Voltage:
200-240 VAC -10% +6%
Frequency:
Single phase 47 to 63 Hz
Current:
10 AMPS maximum steady state
Power:
1100 V·A typical, 2000 V·A max.