background image

 

17 

 
 
 
 

3.2.3  

Photocell 

 
If included in the system, the ambient light sensor (photocell) should be mounted upright, away from 
artificial  light  (such  as  floodlights),  and  in  a  location  that  will  enable  its  sensor  window  to  have  an 
unobstructed view of the polar sky (eg., pointed north in the northern hemisphere).  
Make the connection of the external photocell and the power supply to 

TB1 in the power supply as 

per figure 3-1 page 18

 

3.2.4 

GPS antenna (option) 

 
If  GPS  included  in  the  system,  the  magnetic  antenna  of  the  GPS  should  be  mounted  on  a  ferrous 
metallic  part  without  an  unobstructed  view  to  the  sky.  The  5  meters  cable  provided  with  the  antenna 
shall be connected in the jack plug located in the front side of the GPS module. 

 

3.3 

120VAC to 230VAC Power cable 

 
Make the connection of the AC power supply to 

TB1 in the power supply as per figure 3-1 page 17 

and figure 3-2 page 18 

 

 

3.4       Final Check 

 
Before applying power to the equipment, check all wire connection and ensure that any user-installed 
wiring does not interfere.   

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for OBSTAFLASH Led

Page 1: ...OBSTAFLASH LED INSTALLATION AND OPERATION GUIDE OBSTA 2 rue Troyon 92316 S vres Cedex FRANCE Phone 33 1 41 23 50 15 Fax 33 1 41 23 50 11 www obsta com OCTOBER 2018...

Page 2: ...COLOR white and red white and red white and red POWER SUPPLY 48V 120 230 V 50 60Hz 120 230 V 50 60Hz P N 113738 113739 P12 4E 113733 6P 2E This list is not exhaustive and some modifications can be do...

Page 3: ...turn notice authorizes OBSTA to examine and disassemble returned products to the extent OBSTA deems necessary to ascertain the cause of failure The warranties stated herein are exclusive THERE ARE NO...

Page 4: ...tor includes 2 white led circuits working in active redundancy for the white version and or a red led circuit shared with 2 other projectors Each projector white or dual color comes with a quick conne...

Page 5: ...5 Figure 1 1 POWER SUPPLY COMPONENT LOCATIONS The location of the components can changed depending on the specific demand...

Page 6: ...6 Figure 1 2 POWER SUPPLY COMPONENT LOCATIONS The location of the components can changed depending on the specific demand...

Page 7: ...7 Figure 1 3 OBSTAFLASH 180 COMPONENT LOCATIONS...

Page 8: ...8 Figure 1 5 POWER SUPPLY 113733 6P 2E The size can vary depending on location of the components...

Page 9: ...9 Figure 1 5 POWER SUPPLY 113739 P12 4E The size can vary depending on location of the components Figure 1 5 Size and dimensions of the external photocell option...

Page 10: ...0 mm x w 240 x h 462 mm Surface Area 870cm Wind Load 35 kg at 240 Km h Power Supply 113733 6P 2E Weight 14 kg Dimensions w 300 mm x h 400mm x d 200 mm Power Supply 113739 P12 4E Weight 23 kg Dimension...

Page 11: ...rcuits are indicated by the luminous indicators D6 to D12 on the command card figure 2 1 below Those indicators are normally off and red blinking in case of default 2 2 Command card P N 113744 The com...

Page 12: ...12 Figure 2 1 LUMINOUS INDICATORS ON THE COMMAND CARD...

Page 13: ...13 Figure 2 2 WIRING OF LED CIRCUITS ON THE COMMAND CARD...

Page 14: ...14 Note The configuration of this card is done in the factory and shall not be modified by the end user Figure 2 3 COMMAND CARD...

Page 15: ...ach cabinet a GPS can be installed inside each cabinet for the synchronization This GPS from OBSTA is a DIN rail module that includes 2 led indicators and 2 outputs and comes with an external magnetic...

Page 16: ...cted on the junction box or on the power supply However in the event that they should be disconnected it is very important that the 6 plugs of each projector be correctly mounted and tightened in the...

Page 17: ...3 1 page 18 3 2 4 GPS antenna option If GPS included in the system the magnetic antenna of the GPS should be mounted on a ferrous metallic part without an unobstructed view to the sky The 5 meters ca...

Page 18: ...18 Figure 3 1 TYPICAL WIRING DIAGRAM WITH SYSTEM...

Page 19: ...19 Figure 3 2 TYPICAL WIRING DIAGRAM WITH SYSTEM...

Page 20: ...20 Figure 3 3 TYPICAL WIRING DIAGRAM WITH SYSTEM...

Page 21: ...21 Figure 3 4 WIRING DIAGRAM 113739 P12 4E...

Page 22: ...22 Figure 3 5 WIRING DIAGRAM 113739 6P 2E...

Page 23: ...r supply Some projectors are simultaneously white and red The order of the wires of the cable P N113762 connected on the power cards 1 to 14 is wrong check them according to the main wiring diagram No...

Page 24: ...jectors are not working in red If the 6 projectors not working in red change the power card If 3 projectors are not working disconnect their related circuit from the green connector of the power card...