background image

Installation and operation guide: 
Dual color obstaflash  OFI360-RW-048-U & OFI360-RW-240-U 
16/10/2018

 

OBSTA

 

2 rue Troyon 92316 Sèvres Cedex FRANCE 

Phone : +33 1 41 23 50 10      Fax : +33 1 41 23 50 11 

www.obsta.com

 

Page 
7/15

 

 

 

1.3 Specifications

 

1.3.1 Light output 

Red night 

2.000 ± 25% candelas effective 

Beam Pattern 

360° horizontally; 3°min vertically 

Flash rate 

Type B 
 

Synchronization  

Master / slave mode (one master light can synchronized with other slave 
lights) 

 

1.3.2 Electrical input for 230Vac power supply 113176-240 

Input voltage 

100-240 V +/-10% 

Max current: 

2.2A 

 

1.3.3 Mechanical properties 

1.3.3.1   flash-head (P/N 113790-RR-240) 

 

Weight 

5kg 

Size 

W = 190 mm x H=190 mm x L=220 
 

Surface area 

350cm² 

Wind load 

10kg at 240km/h 

 

1.3.3.2   Power supply (P/N 113176-240) 

 

Weight 

6 kg 

Size 

W = 300 mm x h = 159 mm x L = 300 mm 

1.3.4 Operating environment 

Operating temperature 

-30°C to +55°C 

Humidity 

95% relative humidity 

 

 

 

Summary of Contents for 113790-RR-240

Page 1: ...olor obstaflash OFI360 RW 048 U OFI360 RW 240 U 16 10 2018 OBSTA 2 rue Troyon 92316 S vres Cedex FRANCE Phone 33 1 41 23 50 10 Fax 33 1 41 23 50 11 www obsta com Page 1 15 Edition October 2020 OFC RR...

Page 2: ...List of models Designation Type and Color Input voltage P N OFC RR 240 Red color medium intensity type B 120 240Vac 113790 RR 240 OFC CTR 6E 3F 6A 240 Red color medium intensity type B 120 230Vac 113...

Page 3: ...ion manual specifications or other literature II the items have not been misused or abused in any manner or repairs attempted thereon III written notice of the failure within the warranty period is fo...

Page 4: ...ach system consists of one flash head and can be associated with power supply with ambient light sensor photocell and the interconnecting cable System components are shown in Figures 1 1 to 1 2 1 2 1...

Page 5: ...ration guide Dual color obstaflash OFI360 RW 048 U OFI360 RW 240 U 16 10 2018 OBSTA 2 rue Troyon 92316 S vres Cedex FRANCE Phone 33 1 41 23 50 10 Fax 33 1 41 23 50 11 www obsta com Page 5 15 Figure 1...

Page 6: ...ation guide Dual color obstaflash OFI360 RW 048 U OFI360 RW 240 U 16 10 2018 OBSTA 2 rue Troyon 92316 S vres Cedex FRANCE Phone 33 1 41 23 50 10 Fax 33 1 41 23 50 11 www obsta com Page 6 15 Figure 1 2...

Page 7: ...h rate Type B Synchronization Master slave mode one master light can synchronized with other slave lights 1 3 2 Electrical input for 230Vac power supply 113176 240 Input voltage 100 240 V 10 Max curre...

Page 8: ...LASH is usually mounted at the highest point on the structure on a horizontal platform or as per requirements of the local Aviation Regulation authority in place at the installation location We recomm...

Page 9: ...RW 240 U 16 10 2018 OBSTA 2 rue Troyon 92316 S vres Cedex FRANCE Phone 33 1 41 23 50 10 Fax 33 1 41 23 50 11 www obsta com Page 9 15 2 3 Final check Before power on CHECK The input voltage The wiring...

Page 10: ...10 20 This drawing it covers are the property of OBSTA This document connot reproducted copied or cummunicated with third parties without the authorization of OBSTA Ce document est la propri t d OBS...

Page 11: ...the light output of the light Each flash head do have 2 independent led circuits 3 1 3 Latches The sealing of the light is ensure but the 2 latches and the O ring between flash head and the light bod...

Page 12: ...obsta com Page 12 15 3 1 6 Shunt braid The flash head is attached to the light body through a shunt braid Assure the grounding of the light prevent loosing the flash head during installation PCBa LED...

Page 13: ...night used without photocell Operation The green led GPS blinks the GPS receive the signal The red led D and the green led S blinks The GPS is not synchronized and sends a top sync to the command card...

Page 14: ...e short circuit insulating failure destruction Corrosion Annual Visual Water inside flash head Annual Clean the glass of flash head Bad light output 4 2 Troubleshoot Malfunction 4 2 1Led indicators So...

Page 15: ...chronization Red LED D4 sequence 1 long flash 1 short flash flash head at 15 flash per minute Check the connection of synchronization wires on the command cards both master and slave units GPS Red LED...

Reviews: