Heat Pump Heating Airflow
COMFORT (default) Heat Pump airflow is varied depend
ing on outdoor temperature to maximize comfort.
EFF 325 Fixed airflow used to achieve specified ratings.
This is nominally 325 CFM/ton, but will vary if a 2stage out
door unit is used.
EFF 350 Fixed airflow used to achieve specified ratings.
This is nominally 350 CFM/ton, but will vary if a 2stage out
door unit is used.
MAXIMUM 400 CFM/ton.
Cooling Airflow
COMFORT (default) cooling airflow is varied depending on
humidity and temperature demands settings. This selection en
ables the full dehumidify and comfort capabilities of the system.
When COMFORT is not selected, the unit will not run reduced
airflows for dehumidification.
EFF 325 fixed airflow used to achieve specified ratings –
no dehumidification airflow reduction. This is nominally 325
CFM/ton, but will vary if a 2stage outdoor unit is used.
EFF 350 fixed airflow used to achieve specified ratings –
no dehumidification airflow reduction. This is nominally 350
CFM/ton, but will vary if a 2stage outdoor unit is used.