Appendix B: OMC-150 Specifications
parameter
value
Type of instrument
Anemometer
Measuring principle
Cup and vane
Certification
ATEX Ex ia IIC T4 Gb
ATEX group and category
II 2 G
ATEX Certificate number
IECEx 02
Ex ia IIC T4 Gb
IEXEx Certificate number
Measuring system
ISO
– Metric
Materials of exposed parts
Stainless steel
Material of cups
Polycarbonate with carbon black as antistatic
Ingress Protection
IP-x6 according to EN-60529
Operation Temperature
-
25 … +70 deg. C
Humidity
5 … 90%
Measuring range (wind speed)
0 … 75 m/s
Accuracy (wind speed)
Better than 2 %
Threshold (speed)
Approx. 0.3 m/s
Distance constant
1.68 meters
Measuring range (wind direction)
0
… 360 º (no gap)
Direction accuracy (non-linearity etc.)
2 degrees
Output signal compatibility
Direct connection to Obsermet OMC-158
Speed signal
NAMUR signal according to IEC/EN-60947-5-6
Direction supply voltage
3.3 V nom.
Direction signals
Dual 0..+3.3V analogue voltage signals
Electrical connector type
ITT Canon CA 3102E 16S-1
Pigtail cable length
5 meters
Pigtail cable type
Screened blue signal cable, LAPP Ölflex EB-CY
8x0.75 mm
2
or equivalent.
Overall height (excluding mating plug)
Approx. 905 mm
Overall width (vane mounted)
Approx. 460 mm max.
Mounting method
Pole-mounting bracket with U-bolts (M10) for
mounting on cylindrical or square pole
Clamping range
35 to 60 mm
Weight
Approx. 5 kgs. excluding cable
Packing dimensions
1050 x 510 x 150 mm
Packing weight
10 kgs
Summary of Contents for OMC-150
Page 4: ...Manual OMC 150 Status Final Not confidential Page 4 38 V2 13...
Page 25: ...Manual OMC 150 Status Final Not confidential Page 25 38 V2 13 Example with OMC 158 old...
Page 32: ...Manual OMC 150 Status Final Not confidential Page 32 38 V2 13 Appendix F ATEX certificate...
Page 33: ...Manual OMC 150 Status Final Not confidential Page 33 38 V2 13...
Page 34: ...Manual OMC 150 Status Final Not confidential Page 34 38 V2 13 Appendix G IECEx certificate...
Page 35: ...Manual OMC 150 Status Final Not confidential Page 35 38 V2 13...
Page 36: ...Manual OMC 150 Status Final Not confidential Page 36 38 V2 13...